EasyManua.ls Logo

Festool CT 26 E HEPA - Grounding Instructions; Polarization Instructions; Further safety instructions

Festool CT 26 E HEPA
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAUTION
Risk of injury from tools starting up unex
pectedly
Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con
nected tool is switched off.
The switch [1-8] serves as an On/Off switch. It
has three positions:
Switch position "0"
Appliance socket [1-3] is disconnected from the
power, mobile dust extractor is switched off.
"MAN" switch position
Appliance socket [1-3] is connected to the pow
er, the mobile dust extractor starts.
"Auto" switch position
Appliance socket [1-3] is connected to the pow
er, the mobile dust extractor starts when the
connected tool is switched on.
7 Settings
7.1 Connecting electric power tools
WARNING
Risk of injury
Observe the maximum appliance socket
connected load (see chapter "Technical da
ta")
Switch off the electric power tool.
Connect the electric power tool to the appli
ance socket .
Electrical outlet module circuit breaker
If the maximum connected load at the electrical
outlet module of the power tool is exceeded, the
circuit breaker separates the electrical outlet
module from the voltage supply.
Turn off the power tool using the switch.
Wait approx. 20 seconds.
Activate the circuit breaker [1-4].
Turn the power tool back on.
7.2 Connecting pneumatic tools
WARNING
Risk of injury
Switch off the air tool.
Automatic on/off switch for air tools
(Fehlender Wert_TIM-ProdVariante or
accessories)
with compressed air module in module
slot [1-2]
Recommendation:
Attachment of service unit VE (495886):
compressed air filtered and lubricated
Use of IAS system with IAS connector
(454757) for Festool air tools
Requirement: tool with operating pressure of
6 bar!
7.3 Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera
ture to prevent overheating.
A temperature cut-out switches the mobile
dust extractor off when it reaches a critical
temperature to prevent overheating.
Switch off the mobile dust extractor, allow
to cool for about 5 minutes then switch on
again.
Not possible to switch on: contact
Festool service workshop.
7.4 Adjusting the suction power
Use the rotary knob .
7.5 Applying the brake
Folding out the black brake lever [1-11] pre
vents the mobile dust extractor from rolling. To
achieve this, lift the front end of the mobile dust
extractor slightly and push the black brake lev
er downwards until it latches into place. Push
the green lever again to release.
8 Working
8.1 Handling
Hose store: after finisching work, you can feed
the suction hose through the recess [4-2] and
place it in the hose store.
SysDoc Systainer attachment system: a Sys
tainer can be attached to the storeage area via
the four slides ore the T-Loc [4-1].
English
8

Other manuals for Festool CT 26 E HEPA

Related product manuals