Go to fetco.com for the latest versions of all information Page 6 User Guide & Operator instructions P171 NEW MARCH 2018
.
PROGRAM
Programming Items
Factory set Default
Programming Range
Notes
Batch 1 *
• Batch Summary
Display Summary
Batch1 Summary
Batch Name
Brew Temp.
Brew Volume 4.00
Brew Time
Bypass Vol. 2.00
Total Time

1
90°C
Liter
6:00
Liter
9:30
Summary-continued
Bypass Delay
Number of Pulses
Prewet Percent
Prewet Delay
Drip Delay
Alarm At End
1:00
4
0%
0:00
1:30
NO
• Batch Temp
90 °C
90 °C
|__________[]______|
80 97
This sets the brew
temperature for batch-1
• Brew Volume
4.00 liter
[ 0.50-4:00]
4.00 liter
|__________[]_______|
0.50 6:00
Volume of Coffee (tea to
hot water bypass [2:1])
• Bypass Volume
2.00 liter
2.00 liter
|_______[]_________|
0:00 5.50
Volume of HOT water to
add to hot brew
• Bypass Delay
1:00 mm:ss
1:00 mm:ss
|_[]_______________|
0:00 12:00
Allows for hot water tank
recovery
• Prewet Percent
0%
0 %
|_[]_______________|
0 15
Prewetting helps stabilize
ground coffee
Pause after prewet
spray completes
• Prewet Delay.
0:00 mm:ss
0:00 mm:ss
|_[]_______________|
0 1
This feature appears
ONLY if Prewet >0:00
• Brew Time
6:00 mm:ss
6:00 mm:ss
|________[]_________|
1:00 12:00
• Nr Of Pulses
4
4
|_____[]___________|
1 30
This is a
Safety Feature
• Drip Delay
1:30 mm:ss
1:30 mm:ss
|_____[]___________|
0:30 10:00
NEVER remove
brewbasket during drip-out
• Alarm at End
NO
NO
|______________[]__|
YES ……… NO
Notice
*Batches 1 & 5 are mandatory and are always permanently selected
Batch 2,3,4,6,7&8 may each be selectively hidden with the Batch ON/OFF selector screen
Batch 2
• Batch ON/OFF
ON
ON
|__[]_______________|
ON OFF
• Batch Summary
Display Summary
[See BATCH 1]
• Batch Temp
90 °C
90 °C
|__________[]______|
80 97
This sets the brew
temperature for batch-1
• Brew Volume
4.00 liter
[ 0.50-4:00]
4.00 liter
|__________[]_______|
0.50 6:00
Volume of Coffee (tea to
hot water bypass [2:1])
• Bypass Volume
2.00 liter
2.00 liter
|_______[]_________|
0:00 5.50
Volume of HOT water to
add to hot brew
• Bypass Delay
1:00 mm:ss
1:00 mm:ss
|_[]_______________|
0:00 12:00
Allows for hot water tank
recovery
• Prewet Percent
0%
0 %
|_[]_______________|
0 15
Prewetting helps stabilize
ground coffee
Pause after prewet
spray completes
• Prewet Delay.
0:00 mm:ss
0:00 mm:ss
|_[]_______________|
0 1
This feature appears
ONLY if Prewet >0:00
• Brew Time
6:00 mm:ss
6:00 mm:ss
|________[]_________|
1:00 12:00
• Nr Of Pulses
4
4
|_____[]___________|
1 30
This is a
Safety Feature
• Drip Delay
1:30 mm:ss
1:30 mm:ss
|_____[]___________|
0:30 10:00
NEVER remove
brewbasket during drip-out
• Alarm at End
NO
NO
|______________[]__|
YES ……… NO