Size: 1 Byte, Default Value: 1
Setting Description
0 No reaction
1 Send and alarm frame
Parameter 48: SURGE alarm report
Size: 1 Byte, Default Value: 1
Setting Description
0 No reaction
1 Send and alarm frame
Parameter 49: OVERHEAT and VOLTAGE DROP alarm report
Size: 1 Byte, Default Value: 1
Setting Description
0 No reaction
1 Send and alarm frame
Parameter 50: Active power reports
The parameter defines the power level change that will result in a newpower report being sent. The value is a percentage of the previous report.
Size: 1 Byte, Default Value: 10
Setting Description
0 power reports disabled
1 - 100 (1-100%) - power report threshold
Parameter 52: Periodic active power and energy reports
Parameter 52 defines a time period between consecutive reports.Timer is reset and counted from zero after each report.
Size: 2 Byte, Default Value: 3600
Setting Description
0 periodic reports disabled
1 - 32767 (1-32767 seconds)
Parameter 53: Energy reports
Energy level change which will result in sending a new energy report.
Size: 2 Byte, Default Value: 10
Setting Description
0 energy reports disabled
1 - 255 (0,01 - 2,55 kWh) - report triggering threshold
Parameter 54: Self-measurement
The Dimmer 2 may include active power and energy consumed byitself in reports sent to the main controller.
Size: 1 Byte, Default Value: 0
Setting Description
0 Self-measurement inactive
1 Self-measurement active
Parameter 58: Method of calculating the active power
This parameter defines how to calculate active power. It is useful in acase of 2-wire connection with light sources other than resistive.
NOTE: Parameter 58 is set to 0 after forced auto-calibration.
Size: 1 Byte, Default Value: 0
Setting Description
0 measurement based on the standard algorithm
1 approximation based on the calibration data
2 approximation based on the control angle