Setting Description
0 function disabled
1 - 99 percentage level of brightness
Parameter 20: Switch type
Choose between momentary, toggle and roller blind switch.
Size: 1 Byte, Default Value: 0
Setting Description
0 momentary switch
1 toggle switch
2 roller blind switch - two switches operate the Dimmer 2 (S1 to brighten, S2 to dim)
Parameter 21: The value sent to associated devices on single click
This parameter defines the value sent to devices associated with Dimmer 2 after its enabling.
Size: 1 Byte, Default Value: 0
Setting Description
0 0xFF value is sent, which will set associated devices to their last saved state.
1 Current Dimmer state is sent, which will synchronize brightness level of associated devices (other Dimmers for
example).
Parameter 22: Assign bistable key status to the device status
By default each change of toggle switch position results in action of Dimmer 2 (switch on/off ) regardless the physical connection of conntacts.
Size: 1 Byte, Default Value: 0
Setting Description
0 Device changes status on key status change.
1 Device status is synchronized with key status.
Parameter 23: Double click option
Size: 1 Byte, Default Value: 1
Setting Description
0 double click disabled
1 double click enabled.
Parameter 24: Command frames sent in 2-nd and 3-rd association groups (S1 associations)
Parameter determines, which actions will not result in sending framesto association groups.
NOTE: Parameter 24 values may be combined, e.g. 1+2=3 means that associations onswitching ON or OFF the Dimmer 2 (single click) will not be sent.
Size: 1 Byte, Default Value: 0
Setting Description
0 all actions send to association groups
1 do not send when switching on the Dimmer (single click)
2 do not send when switching off the Dimmer (single click)
4 do not send when changing dimming level (holding and releasing)
8 do not send on double click
0 all actions send to association groups
Parameter 25: Command frames sent in 4-th and 5-th association groups (S2 associations)
Parameter determines, which actions will not result in sending frames to association groups.
NOTE: Parameter 25 values may be combined, e.g. 1+2=3 means that associations onswitching ON or OFF the Dimmer 2 (single click) will not be sent.
Size: 1 Byte, Default Value: 0