EasyManua.ls Logo

Field Controls 46334200 - Page 4

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 4
SWG-4AT AMERICAN STANDARD AND TRANE
SIDEWALL POWER VENTING KIT
Field Controls P/N 46205405
Kit Includes:
SWGII-4HD Sidewall Power Venter
CK-43F Control Kit
Includes: 4" MG-1 Barometric Draft Control
Fan Proving Switch
Fixed post purge
For Use With The Following American Standard And Trane Furnaces:
AUD-C CUE-A ADD-R
TUD-C TUE-A TDD-R
AUD-R ADD-C CDE-A
TUD-R TDD-C TDE-A
Furnace Configuration And Vent Pipe Restrictions:
Furnace Input
BTU/Hr
Diameter Of Vent Pipe
Collar On Furnace (In.)
Maximum Equivalent
Vent Length (Ft.)
40,000 4 65
60,000 4 65
80,000 4 65
100,000 4 65
120,000 4 65
140,000 4 65
General Wiring
Refer to the Diagrams on the following page for guidance in wiring the Power Venter and Control Kit
to the appliance.
For complete installation information refer to the Field Controls SWG-4AT Power Venter Installation
Manual for details (P/N 46306700.)

Related product manuals