EasyManua.ls Logo

Fieldpiece Job Link SC480 - Voltage and NCV Measurements; Volts AC (VAC) Measurement; Volts DC (VDC) Measurement; Non Contact Voltage (NCV) Detection

Fieldpiece Job Link SC480
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1312
Measurement Dial
Volts AC (VAC) True RMS (50-400Hz)
Test power lines (120 to 480VAC), test 24VAC going to controls and test
for transformer failure.
Ranges: 1000mV, 10V, 100V, 750V Resolution: 0.1mV
Accuracy: ±(1.5% + 10) 50Hz to 60Hz
±(2.0% + 10) 60Hz to 400Hz
Unspecied at 400Hz and greater
Minimum Input Voltage Range: >20 digits
Low Pass Filter: >1 kHz
Crest Factor: ≤ 3
Audio/Visual Hi-V Indicator: >30VAC/VDC
Input Impedance: 5MΩ
Overload Protection: 1000VDC or 750VAC rms
Volts DC (VDC)
Select VDC and measure DC voltages on circuit boards on more
advanced HVACR systems and logic control boards.
Ranges: 1000mV, 10V, 100V, 1000V Resolution: 0.1mV
Accuracy: ±(0.5% + 5)
Input Impedance: 5MΩ
Overload Protection: 1000VDC or 750VAC rms
Non Contact Voltage (NCV)
Use NCV to check 24VAC from a thermostat or live voltage up to 600VAC.
Always test a known live source before using. A segment graph and RED
LED will display the presence of voltage. An audible beep increases from
intermittent to continuous as intensity of eld (EF) increases.
AC Voltage Detection Range: 24VAC to 600VAC (50-60Hz)