Patent Pending
Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • (510) 441-1100 • Fax: (510) 441-1510 • www.finelite.com
2 of 13
© 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form CE - 98532. 03/18
HP-2 / HP-4 / HP-6 Recessed or Regressed Spackle & Visible Flange Mitered Corner
Installation Instructions
Step 1 - Rough-Ins & Mounting Options
Rough-In Widths
Total Run Length
W
CONTINUED
X1 X2
Y2
L1
L2
Rough-In Lengths
Y1
Starter
ID: 1
Joiner
ID: 2
Ender
ID: 3
Z = Mounting Hole Location
(Does not include endcaps)
HP-2 5"
HP-4 6"
HP-6 6-1/2"
X = Luminaire section length (Does not include endcaps)
Y1 = Total run length of luminaire (Does not include endcaps)
Y2 = Total run length of luminaire (Does not include endcaps)
Z = Mounting hole location
Refer to Record Drawings and building plans to determine
exact mounting, suspension points, and power feed locations.
• Use rough-in Length & Width dimension and Record Drawings to determine rough-in measurements.
• Build wall/ceiling with rough-in according to rough-in dimensions.
• CRITICAL: Drywall or weak paneling must be secured to blocking (studs) around rough-in opening in
the wall/ceiling.
Spackle Flange (SF)
W
Visible Flange (VF)
W
* Tolerance +/- 1/16"
L1 & L2 = Total Run Rough-In Length*
Spackle Flange Visible Flange
L1 L2 L1 L2
HP-2 Y1 + 7/16" Y2 + 7/16" Y1 + 5/16" Y2 + 5/16"
HP-4 Y1 + 9/16" Y2 + 9/16" Y1 + 7/16" Y2 + 7/16"
HP-6 Y1 + 7/16" Y2 + 7/16" Y1 + 5/16" Y2 + 5/16"
This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary.
Z
Z
Z
Z
Endcap
Endcap
W = Rough-In Width*
Spackle Flange Visible Flange
HP-2 3-1/8" 2-7/8"
HP-4 4-7/8" 4-1/4"
HP-6 6-1/8" 5-7/8"
* Tolerance +/- 1/16"