HP-2 / HP-4 / HP-6 Recessed or Regressed Spackle & Visible Flange Mitered Corner
Installation Instructions
Step 1 - Rough-Ins & Mounting Options
This is a hypothetical build to show the capabilities of this luminaire family and mount type. Your build may vary.
1/4"-20 Washer & 1/4"-20 Nut
(by others)
1/4" Threaded Rod
(by others)
Drywall Ceiling/Wall Drywall Ceiling/Wall
Structure Support (by others)
1/4" Lag Bolt
(by others)
• Luminaire mounting holes sized for 1/4"-20 threaded rod.
• Refer to Record Drawings to determine mounting hole locations on luminaires and install threaded rods to structure.
• Distance from threaded rod to wall/ceiling surface
1
must be a minimum of 3-1/2".
• Refer to Record Drawings to determine mounting hole locations on luminaires and install support blocking² to structure.
• Distance from support block to wall/ceiling surface
1
must be a minimum of 4-1/8".
3-1/2" min.
4-1/8" min.
Support
Blocking
2
(by others)
Support
Blocking
2
(by others)
Mounting Options
Option 1 - Mount to Threaded Rod Option 2 - Mount to Structure
1/4"-20 Washer
(by others)
1/4"-20 Nut
(by others)
Mounting Option 1
Threaded Rod
(by others)
¹ Wall/ceiling surface = drywall, wood, concrete or masonry, metal panels, tile, etc.
² Support blocking = Wooden beams/studs, sheet metal framing beams, steel beams, concrete beams, etc. Use hardware appropriate to the beam material.
1/4"-20 Lag Bolt
(by others)
Mounting Option 2