13
willsoundaloudaudiblealarm(85dBat1m
(3feet))andtheAlarmLEDbelowthe
symbolonthefrontofthedetectorwill
ashredonceeverysecond.
The Alarm will sound:
Between60and90minuteswhen
exposedtoaminimumof50ppmofCO.
Between10and40minuteswhen
exposedtoaminimumof100ppmofCO.
Within3minuteswhenexposedtoa
minimumof300ppmofCO.
Alarm silence:
It is possible to temporarily silence the
alarm up to two times if the level of CO
that triggered the alarm is less
than 200ppm. After ventilating
the property you can temporarily
silence the alarm by pressing the
Test/Mode button, the alarm will stop and
thesilencemodesymbolwillappearonthe
screen.Thesilence modewilllastfor up to
3minutes.IftheCOlevelremains toohigh
thealarmwilltriggeragainorifthelevelof
CO rises above 200ppm then the detector
willautomaticallyre-enteralarmmode.Ifthe
levelofCOhasfallentoasatisfactorylevel
thesilencemodeiconwilldisappear,theunit
willexitalarmmodeandthesegmentsofthe
bargraphwillslowlydisappearastheCOin
thesensorclears.
Alarm in absence:
IfthePeaklevelreadingsymbolis showing
on the screen but there is no full alarm
sound and you are not pressing
the test button, then your
detector is warning that it has
detectedCarbonMonoxideinyourabsence.
Immediately vacate the premises and seek
medical attention for anyone su󱐯ering
the e󱐯ects of CO poisoning (headache,
nausea, see page 3). Treat this as a serious
warning. Call a qualied technician and
havetheprobleminvestigatedandrectied
immediately. For usefull contact numbers
seepage17.
Error signal:
Theunitcontinuouslychecksthesettingsof
its sensor and circuitry. If any
of these settings are found to
be incorrect, the detector will
emitasinglechirponceperminuteandthe
displaywillshow“Err”forerrorandanerror
code,cyclingbetween“Err”andtheparticular
errorcode.
Low power pack signal:
If the power pack becomes low then
the detector will emit a single chirp
once per minute and the low power
packiconwillashonthescreen.
IMPORTANT: A single chirp once per
minutetogetherwithanerrorsignalor
lowpowerpackwarningdoesNOTmeanthat
thedetectorhasdetectedcarbonmonoxide.
If you experience an error condition or low
power pack warning and the product is