EasyManua.ls Logo

Fireboy- Xintex CMD6-MB - Operation of Fireboy-Xintex Carbon Monoxide Alarm(s); Status Indicators and Explanations

Fireboy- Xintex CMD6-MB
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Part Number 18160, F, 06/29/2021
Operation of Fireboy-Xintex Carbon Monoxide Alarm(s)
Should a very high level of carbon monoxide exist, the CO Alarm will alarm in a few minutes.
However, if small quantities of CO are present or high levels are short-lived, the micro controller
will accumulate the information and determine when an alarm level has been reached. This
feature eliminates nuisance alarms. For example, in a boat it is possible to see high levels of CO
for a very short time such as when docking or maneuvering. The CO Alarm takes this all under
consideration by totaling the quantity of CO detected over a period of time.
The CO Alarm is programmed to alarm at a COHb level of 10%. Alarm points are 70 ppm (60-240
minutes), 150 ppm (10-50 minutes), and 400 ppm (4-15 minutes). Alarm will clear when the CO
level drops below 40 ppm.
Status Indicators and Explanations
SYSTEM
Red LED
AUDIBLE
STATUS
INDICATOR
HORN
Normal:
Off
Off
Alarm:
1 Flash/5 sec.
4 Beeps, 5 sec. Silence
Remote Alarm:
1 Flash/5 sec.
4 Beeps, 5 sec. Silence
End of Life
1 Flash/5 sec.
1 Beep/60 sec.
Power Indicator
Alarm Indicator
Horn
Test/Mute Button