FACTORY DEFAULT
ELECTRIC CONNECTION ( with three way brass mixing valve )
ELECTRIC CONNECTION ( with four way brass mixing valve )
Themotorisequippedwithcordofconnectiontothe mains.Whenconnectingthedrive itisnotnecessary to openit.
The motor is equipped with cord of connection to the mains. When connecting the drive it is not
necessarytoopenit.
Red dial of
rotating angle
0
10
Incision shows
rotor position in valve
2. Boiler on left
2. Boiler on left
1. Boiler on right
D.) Inlet from left
C.) Inlet from bottom
! WARNING !
Electrical connection to the mains can be performed only by qualified person in compliance
with local regulations.
Actuator's output position
in valves axis
Actuator's output position
in valves axis
0
10
Actuator
position
1. 2. Boiler on right
Incision shows
rotor position in valve
Red dial of
rotating angle
0
10
Actuator
position
Red dial of
rotating angle
0
10
Actuator
position
Red dial of
rotating angle
0
10
Actuator
position
9
3
L
N
8
2
M
7
1
brown
blue
black
wh/red
ye
wh/blue
ye/gr
TA
9
3
L
N
8
2
M
7
1
brown
blue
black
wh/red
ye
wh/blue
ye/gr
TA
9
3
L
N
8
2
M
7
1
brown
blue
black
wh/red
ye
wh/blue
ye/gr
TA
9
3
L
N
8
2
M
7
1
brown
blue
Black
wh/red
ye
wh/blue
ye/gr
TA