CM6000 Install Guide
Alarm and Starter System
www.firstechonline.com | www.compustar.com
Connector 2 (CN2), 2-Pin: Optional Battery Back-up
Pin 1 Red - Constant 12 V positive (+) input and (+) charging output.
Pin 2 Black - Ground (-) negative input.
Connector 3 (CN3), 20-Pin: Programmable Output Channel (POC)
IMPORTANT: Odd Pin numbers 3 through 19 are programmable for up to 19 different output types.
Refer to Special Option Group 2 for complete details.
Pin 1 Blue - 250mA negative (-) output when armed and during remote start (while running). This wire is
pre-wired to the anti-grind/starter-kill relay. Caution: When this wire is being used to trigger
aftermarket accessories it must be diode isolated.
Pin 2 Orange/Black - Parking Light Reminder (-) input that monitors the vehicle’s parking lights.
Pin 3 Green/White [POC 1] - Parking light 250mA negative (-) output. The proper wire will test (-) when
the parking light switch is in the on position.
Pin 4 Light Blue – Parking / Emergency brake negative (-) input. This input is required for manual
transmission/reservation and turbo-timer mode. The proper wire will provide a (-) trigger when
parking / emergency brake is set and ignition is on.
Pin 5 Red/Black [POC 2] – 2nd Starter 250mA negative (-) output. This output provides a negative (-)
trigger output during remote start crank.
Pin 6 Light Blue/White - Brake 12V positive (+) input. This input must be connected as it provides a shut
down for the remote start. The proper wire will test (+) 12V while the foot brake is pressed.
Pin 7 Green [POC 3] - 2nd Ignition 250mA negative (-) output. This output provides a negative (-) trigger
upon remote start, throughout the crank and during remote start.
Pin 6 Green/White – This is a dual-purpose wire that features selectable functionality thru the parking
light/trunk output jumper on the control module. It is either a positive (+) parking light output or
positive (+) trunk output. This wire carries a 10 amp fuse.
Default - Parking light positive (+) output. The proper vehicle wire will test (+) 12V when the parking
light switch is in the on position.
Optional – Trunk release positive (+) output. The proper vehicle wire will test (+) 12V when the trunk
release is triggered.