15
Installation instructions
Natural gas LPG
Test Point Pressure [kPa] 1.0 2.75
BURNER
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Semi-rapid
1.17 6.50 0.70 6.30
Triple-ring wok
1.54 11.88 0.98 12.00
Dual
0.76
(inner crown)
16.20
(inner and
outer crowns
operating)
0.50
(inner crown)
16.20
(inner and
outer crowns
operating)
1.23 - no.2
(outer crown)
0.73 - no.2
(outer crown)