8
INSTALLATION INSTRUCTIONS
If you have an uncontrolled water heating source (eg a wet back or solar heating
system) you should fit a Hot ‘N’ Safe Valve. This will ensure the hot water temperature
remains within safe limits.
Hot ‘N’ Safe Valves available are:
RMC TVA 50HF
RMC TVA 75HFS
Adjustable between 35°C – 55°C
RMC TVA 50HP
For instantaneous gas hot water supply
Water supply requirements:
Inlet water pressure: Maximum 1MPa (150psi), Minimum 30kPa (4.5psi)
Inlet water flow rate: Minimum 6litres/minute
Cold supply only:
If you only have a cold water supply, the inlet valve cap (blanking cap) which came with
your washer must be connected to the hot inlet valve. The cap prevents water leaking
out of the hot valve. This appliance incorporates backflow protection complying with
AS3500.1. No further backflow protection is required for connection to the water supply.
Note: your washer has an internal heater to heat water. If you do not connect a hot
water inlet hose, your washer will automatically recognise there is no hot water supply
and its internal heater will heat the cold water to the selected cycle temperature.

Other manuals for Fisher & Paykel WH8060F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fisher & Paykel WH8060F and is the answer not in the manual?

Fisher & Paykel WH8060F Specifications

General IconGeneral
BrandFisher & Paykel
ModelWH8060F
CategoryWasher
LanguageEnglish

Related product manuals