Instruction Manual
D200119X012
2100 and 2100E Liquid Level Switches
June 2017
5
ATEX— II 2 G D
IECEx— Ex d IIC T4/T5/T6 Gb ; Ex tb IIIC Txx_C Db
Model 057-0770: Gas Ex d IIC T6 (Ta = -40_C to +70_C) (5 A Max) ; Ex d IIC T5 (Ta = -40_C to +75_C) (11 A Max)
Dust Ex tb IIIC T85_C Db IP6X (Ta = -40_C to +70_C) (5 A Max) ; Ex tb IIIC T100_C Db IP6X (Ta = -40_C to +75_C)
(11 A Max)
Model 057-0771: Gas Ex d IIC T6 (Ta = -40_C to +70_C) (5 A Max) ; Ex d IIC T4 (Ta = -40_C to +65_C) (11 A Max)
Dust Ex tb IIIC T85_C Db IP6X (Ta = -40_C to +70_C) (5 A Max) ; Ex tb IIIC T135_C Db IP6X (Ta = -40_C to +65_C)
(11 A Max)
Special Conditions for Safe Use:
Each Electrical Snap-Switch Assembly shall be installed such that the equipment wiring is protected from
mechanical damage. The equipment wiring must not be subjected to tension or torque. If it is to be terminated
within a potentially explosive atmosphere, a suitably certified termination facility must be used.
UL— Class I Division 1 Groups A,B,C,D ; Class II Division 1 Groups E,F,G
2100E Electric Switch Assembly
Customs Union (Russia, Belarus, Kazakhstan and Armenia)— Certificate number TC RU C-US.ГБ6.B.00466; 1Ex d IIC
T4/T5/T6 X, IP66
Ambient Temperature:
T4 DPDT, 11 A maximum current, -40 to 65_C
T5 SPDT, 11 A maximum current, -40 to 75_C
T6 SPDT and DPDT, 5 A maximum current, -40 to 70_C
Conditions of Application
1. Level switch type 2100E should be used according to the given Ex-marking, requirements of CU TR 012/2011,
GOST 30852.13-2002 (IEC 60079-14:1996), current “Electrical plant arrangement rules” (PUE, art. 7.3),
“Technical maintenance rules for electrical plants” (PTEEP, art. 3.4), other normative documents regulating
application of electrical equipment in explosive areas, and manufacturer’s instruction manual.
2. Potential Ex application areas of level switch, categories and groups of explosive gas and vapors mixtures with air
– according to requirements of GOST 30852.9-2002 (IEC 60079-10:1995), GOST 30852.11-2002 (IEC
60079-12:1978) and “Electrical plant arrangement rules” (PUE, art. 7.3).
3. Level switch must be used with approved cable glands and plugs that provide the required type and level of
protection and ingress protection.
4. Sign «X» after the Ex mark means that the electrical switch type 057-07 ** as part of an electronic module
comprising a level switch comes with a permanently attached cable. Connecting the free end of the cable to the
external device should be in accordance with the operating instructions and the requirements of GOST
30852.13-2002.
5. Changes in controller construction, concerning the explosion means, should be approved by Accredited Testing
Body.