ADJUSTMENT
PROCEDURES
(continued)
FOCUS
GAIN
ADJUSTMENT
1.
Apply
P202
to
the
center
position,
and
place
the
test
disc
1.
KICK
GAIN
ADJUSTMENT
Place
the
test
disc
(Modern
Wave
I)
on
the
table
load.
(Modern
Wave
II)
on
the
table
load.
2.
Set
the
oscilloscope
to
NORMAL
TRIG.,
set
the
EXT.
2.
Connect
the
measurement
tool
described
in
the
last
sec-
TRIG.
pin
to
external
trigger,
and
input
the
trigger
from
tion
to
focus
coil
pin
(CN2).
test
terminal
(CN11-2)
TRH
pin
to
the
oscilloscope.
3.
Apply
Power
Switch
to
the
set
and
PLAY
the
first
item
on
3.
Next
connect
test
terminal
(CN10-3)
HF
pin
to
Channel
1
the
test
disc.
Now
apply
a
signal
of
900Hz
and
0.3Vp-p
of
the
oscilloscope,
and
connect
test
terminal
(CN12-3)
from
the
signal
generator
to
the
measurement
circuit.
TE
pin
to
Channel
2.
4.
Set
the
oscilloscope
to
X-Y
operation,
and
while
observ-
4.
Apply
Power
Switch
to
the
set
and
PLAY
the
first
item
on
ing
the
lissajous
waveform
adjust
P202
to
the
point
where
the
phase
difference
is
90°
as
shown
in
Fig.
5
below.
the
test
disc,
and
the
press
the
PAUSE
button.
Now
ob-
serve
the
waveforms
for
HF
and
TE
with
triggers
applied
from
test
terminal
(CN11)
TRH
pin.
At
this
point,
adjust
P206
so
that
a
kick
pulse
waveform
of
about
1.5
tracks
as
shown
in
Fig.
6
below
is
obtained.
wm
-<—
Tracking
Error
Out
Pe
d40a
hod40
ms
Fig.
5
HF
waveform
TRACKING
GAIN
ADJUSTMENT
1.
Apply
P204
to
the
center
position,
and
place
the
test
disc
(Modern
Wave
IL)
on
the
table
load.
2.
Connect
the
measurement
too!
described
in
the
last
sec-
tion
to
the
tracking
coil
pin
CN2.
3.
Apply
Power
Switch
to
the
set
and
PLAY
the
first
item
on
‘le
the
test
disc.
Now
apply
a
signal
of
1350Hz
and
0.3Vp-p
from
the
signal
generator
to
the
measurement
circuit.
4.
Set the
oscilloscope
to
X-Y
operation,
and
while
observ-
ing
the
lissajous
waveform
adjust
P204
to
the
point
where
the
phase
difference
is
90°
as
shown
in
Fig.
5
above.
NOTE:
Adjustment
must
be
performed
so
curve
section
in
Fig.
6
appears.
Fig.
6
ACCESS
OPERATION
CHECK
Vary
the
FREE
RUN
FREQUENCY
from
a
center
value
of
4.3218MHz
to
+50kHz
(4.2700MHz
~
4.3700MHz),
and
have
the
pick-up
search
from
the
track
closest
to
the
center
to
the
outermost
track
and
then
back
into
the
track
nearest
the
center,
to
check
that
operation
is
stable.
NOTE:
After
this
adjustment
is
completed,
be
sure
to
adjust
back
If
these
two
adjustments
are
performed,
the
TRACKING
to
4.3218MHz.
OFFSET
must
also
be
adjusted.