ADJUSTMENT
PROCEDURES
(continued)
10K
oQ47
E
10K
0.047
uD
GND
Dualtrace
Oscilloscope
10K
0.047
10K
0.047
F
4.
Press
the
F
FWD
button.
The
TRACK
No.
indication
is
“2”
and
the
disc
begins
to
rotate.
Continue
to
press
the
PLAY
button.
The
unit
is
rotating
in
this
state
with
the
tracking
servo
turned
off.
5.
Observe
the
resurge
waveform
of
the
waveform
indicated
on
the
oscilloscope
and
insert
the
adjustment
jig
into
the
diffraction
grid
holes
to
adjust
the
diffraction
grid
so
that
the
phase
difference
is
180°.
6.
Even
if
the
phase
difference
E
is
180°
in
the
above
step,
the
&
and
F
beams
may
be
mistakenly
on
two
different
beam
pit
tines
as
shown
below.
F
Main
Be
sure
that
the
E
and
F
beams
are
in
the
same
pit
line
for
subsequent
adjustments.
2
7.
Remove
the
short
between
test
pin
TP1
and
GND,
and
TEST
1
and
GND,
and
play
back
the
fourth
selection
on
YEDS4.
8.
Observe
the
waveform
of
the
signal
between
test
pin
E
and
test
pin
F
using
the
dualtrace
oscilloscope
£
(Monitored
in
ALT
mode).
The
beam
E
and
beam
F
are
in
the
same
pit
line
if
the
trigger
of
waveform
F
is
approximately
254s
behind
the
point
(Position
where
waveform
holiows
out}
where
the
waveform
E
is
The
twobeam
are
on
the
same
pit
line.
triggered.
(100mV/DIV
:
5«Sec/DiV)
When
observation
of
the
waveform
is
difficult,
the
trigger
level
can
be
varied.
When
the
beams
are
not
in
the
same
line,
return
to
step
1,
and
rotate
the
adjustment
jig
at
the
180°
point.
Confirm
that
the
beams
are
in
line
at
the
180°
point.
Repeat
steps
1
to
7
until
confirmation
of
this
is
possible.
Note:
When
the
pick-up
is
replaced,
it
is
adjusted
as
a
unit,
and
beams
E
and
F
can
be
brought
in
line
and
the
phase
made
180°
by
a
slight
adjustment.
Slightly
rotate
the
adjustment
jig
when
making
adjustment.
if
the
beams
come
out
of
line,
it
is
difficult
to
bring
them
back
into
the
same
pit
fine.
ADJUSTMENT
OF
PICK-UP
ANGLE
1.
Mount
the
test
disc
YEDS4
on
the
turntable.
2.
Turnon
the
power
and
play
back
the
fourth
selection.
3.
Connect
the
oscilloscope
between
test
pin
HF
and
test
pin
GND.
Monitor
the
waveform
of
HF
and
rotate
the
angle
adjustment
screw
so
that
the
waveform
is
at
its
maximum.
2
E-F
BALANCE
ADJUSTMENT
1.
Turn
on
the
power
switch
and
mount
test
disc
YEDS4
on
the
table
load.
Set
the
unit
to
the
STOP
mode.
2.
Short
test
pins
TEST1
and
GND
of
connector
CN16.
3.
Short
test
pin
TP1
and
test
pin
GND,
and
connect
a
DC
Voltmeter
and
oscilloscope
to
test
pin
TE
of
connector
CN15
through
the
low-pass
filter
shown
below.
Angle
Adjustment
Screw
22K
TE
‘
|
DC
Voltmeter
!
and
|
Oscilloscope
GND
4,
Press
the
F
FWD
button.
The
TRACK
No.
indication
is
“2”
and
the
disc
begins
to
rotate.
Continue
to
press
the
PLAY
button.
The
unit
is
rotating
in
this
state
with
the
tracking
servo
turned
off.
5.
Adjust
P101
so
that
the
DC
Voltmeter
and
oscilloscope
is
OV+15mvV.
ADJUSTMENT
PROCEDURES
(continued)
ADJUSTMENT
OF
TURNTABLE
HEIGHT
This
adjustment
must
be
made
when
the
motor
is
replaced.
1.
Attach
the
turntable
so
that
its
top
surface
is
11.9mm
_
from
the
top
of
the
chassis.
+
Spindle
Motor
2.
Connect
test
pin
FC
of
connector
CN14
to
a
DC
Voltmeter
and
oscilloscope
through
the
low-pass
filter.
22K
FC
DC
Voltmeter
and
Oscilloscope
GND
3.
Turn
on
the
power
switch
and
playback
the
first
selection
on
test
disc
YEDS4.
4,
Readjust
the
height
of
the
turntable
if
the
reading
on
the
DC
Voltmeter
is
not
in
the
range
of
OV+0.25V.
(Increase
the
height
of
the
turntable
when
the
OC
Voltmeter
reading
is
positive,
and
decrease
it
when
negative.)
ADJUSTMENT
OF
FOCUS/TRACKING
GAIN
The
measurement
circuit
shown
below
is
necessary
for
accurate
adjustment
of
the
focus
and
tracking
gain.
If
this
circuit
cannot
be
made,
make
adjustments
using
the
simplified
procedure.
@
Remove
connector
CNS
from
the
pick-up
and
connect
the
measurement
circuit
between
the
PCB
and
=
wmanece.
Pick-up.
is
@
The
iC
used
is
TA7256P.
@
Volume
—
control
2k0-B
shorts
IN
and
SG.
1kHz
1Vp-p
is
supplied
from
the
signal
generator,
and
adjustment
is
made
for
Pick-up
minimum
output
from
OUT.
CNS
-
Simplified
adjustment
Procedure
®
Focus
gain
adjustment
P102
is
set
to
a
mechanical
center.
e@
Tracking
gain
adjustment
P103
is
set
to
a
mechanical
center.
Precise
adjustment
procedure
@
Focus
gain
adjustment
1.
Connect
the
measurement
circuit
shown
above,
turn
on
the
power
switch,
and
mount
the
test
disc
YEDS4.
2.
Playback
the
first
selection
on
the
test
disc,
and
apply
a
1,000Hz
0.5Vp-p
signal
from
the
signal
generator.
3.
Observe
the
resurge
waveforms
on
the
oscilloscope,
and
adjust
P102
so
that
the
phase
difference
of
outputs
X
and
Y
from
the
measurement
circuit
is
90°.
@
Tracking
gain
adjustment
1.
Adjustment
is
made
in
the
same
manner
as
for
focus
gain.
The
input
from
the
frequency
generator
is
set
to
1,000Hz,
0.5Vp-p,
and
P103
is
adjusted
so
that
the
phase
difference
is
90°.
Dualtrace
Oscilloscope