SETUP GLOBAL
Global settings are made in the SETUP menu, which apply to all scenes. Press the
SETUP button to enter the menu. Step through the parameters by pressing the SETUP
button several times. The display shows the menu name and the associated value by
flashing. Change the value with the DATA controller. When the value is changed, the
SETUP settings are automatically saved permanently.
The following parameters can be set:
"USr" - Assignment of the USER 1+2 sockets
"FSn" (USER1=FILL function, USER2=SENS-SET function)
"SCE" (USER1=Scene down, USER2=Scene up)
"FCL" (USER1=FILL, USER2=Clear Position)
"CLi" - Function of the CLOCK input socket
"oFF" (no function)
"16" (16th clock)
"96" (96 ticks per bar)
"CLo" - Function of the CLOCK output socket
"oFF" (no function)
"16" (16th clock)
"96" (96 ticks per bar)
"rSI" - Function of the RESET input socket
"oFF" (no function)
"rES" (trigger pulse reset sequence)
"trS" (trigger start/stop)
"run" (Toggle: high=Play, low=Stop)
"rSo" - Function of the RESET output socket
"oFF" (no function)
"r01".. "r32" (reset after 1-32 cycles = short trigger pulse)
"trS" (sends trigger at start and stop)
"run" (toggle at play=high, stop=low)
"PtC" - Pattern change per beat or on the fly
"bAr" (pattern change to the next bar)
"FrE" (Free - pattern change immediately)
"bCo" - Auto BAR Copy
“On” (switched on)
“oFF” (switched off)
Auto Bar-Copy is the automatic copying of the bars into the remaining bars with the fol-
lowing BAR settings:
BAR=1 Bar 1 is also copied to bar 2,3,4 (when changing bar to 2 or 4)
BAR=2 Bars 1+2 are also copied to 3+4 (when bar changes to 3)
BAR=3+4 do nothing!
"ALd" - Auto load (Scene which is loaded when switching on)
"01-50" (Scene number 01-50)
"SUn" - Sensor setting for indoor/outdoor operation to avoid interference from the sun
“On” (sensors less sensitive)
“oFF” (sensors more sensitive)