Electrical
Systems
A WARNING
Do not modify the generator installation or exhaust
system in any
way.
Do not use the generator as
an
emergency power
source to a general residential or industrial utility line.
This
is
illegal and may cause shock or electrocution to
power line utility personnel attempting to repair power
lines.
A WARNING
Do
not block the generator ventilating air inlets or out-
lets. The engine requires a constant supply of cooling
air.
Restricted ventilating air inlets or outlets
can
cause engine failure.
A WARNING
Exhaust gases are deadly. Inspect the generator
exhaust system thoroughly before starting the gener-
ator engine. Do not block the tail pipe or situate the
motor home
in
a place where the exhaust gases have
any possibility
of
accumulating either outside, under-
neath, or inside your vehicle or any nearby vehicles.
Outside air movements can carry exhaust gases
inside the vehicle through windows or other openings
remote from the generator exhaust.
Operate the gen-
erator only when safe dispersion
of
exhaust gases
can be assured, and monitor outside conditions to
be
sure that exhaust gases continue
to
be
dispersed
safely.
Generator Fuel Supply
Fuel
for the gasoline or diesel genel:ator is taken
from the main fuel tank through a special feeder
tube which is higher
in
the tank than the feeder
tube to the motor home engine. This arrange-
ment prevents the generator from running the
motor home fuel tank dry.
Propane Generator (If Equipped)
Fuel is provided from a dedicated Propane tank.
Generator Operations
To
start
the generator:
1. Press generator remote switch until generator
is running.
08-6
2. To stop the unit, press switch and release.
If
the generator is slow to start, DO NOT hold
the switch
in
the START position for more than
10 seconds. Release the switch, wait
15
sec-
onds, then try to start again. This will help avoid
overheating and damage to the generator start-
ing system.
/1
NOTE 1
Refer to the generator operating instructions provided
in your
Owner's
Information
Package for informa-
tion before starting the generator.
Do
not start
the
generator unit with a heavy
power
load. Always wait
at
least three minutes after starting generator before
turning on (or plugging in) heavy electrical loads, such
as the roof air conditioner.
ENERGY MANAGEMENT SYSTEM -
50 AMP FOR ADDITIONAL
APPLICATION
Intellitec's Smart Energy Management System -
50 AMP (Smart EMS) is designed to be used
in
RV
s equipped with 50 AMP electrical service.
The system senses when the coach is connected
to a
50 AMP service and allows simultaneous
operations
of
all the 120 volt loads. When 50
AMP
service is not available and the coach is
connected to a smaller electrical service, such as
a generator source,
30 AMP
or
20 AMP service,
the system automatically takes control
of
the
loads to practically eliminate circuit breaker trip-
ping.
It
constantly monitors the total amount
of
current drawn
in
the
RV
and controls the loads,
as necessaly, to keep the total current to a value
less than, or equal to, the available power serv-
ice.
There is no programming necessary and the unit
will work with any load within the circuit
breaker limits. The Smart
EMS
automatically
"learns" the amount
of
current drawn by each
of
the controlled loads
as
it turns them "ON" and
"OFF". In this way, it automatically adapts
to
differing loads or loads whose
CUtTent
changes
with line voltage or temperature.