Flex-Pro
7.0 Pump Output Speed Adjustment
Press UP arrow to increase pump output. Press DOWN arrow to increase
pump output.
8.0 Contact Closure Input (Remote Start/Stop)
Used to remotely start and stop the pump using a close=run or open=stop signal. If the pump must
start when the loop is open, then select “Close: Stop Pump” option. Can be used with an external
foot pedal, a PLC, contact closure, or other similar external devices.
Default settings: Disable
CC Input Range: 6 - 30 VDC
or
Dry Contact Closure (no voltage required)
[See section 5.1 for wire connections]
Navigate to Contact Input menu by holding the START button for 5 second. While motor is off.
Press UP or DOWN arrow to scroll through your options.
Press START to make a selection. The radio button (square box) is now filled in next to your
selection.
Press DOWN arrow to scroll down to Done selection. Then press START.
IMPORTANT: To begin operation, press the START button to place pump in STANDBY. The display
background will turn blue indicating the pump has been stopped remotely. When the pump is
started by the remote contact, the display background will turn green.
IMPORTANT: If the Contact Closure Input is enabled, the pump will display STANDBY if the pump
has been stopped by the Remote Contact Closure. Please use caution in this mode as the pump
may Start at anytime. If you must perform maintenance to the pump, Press STOP button.
When Contact Closure Input is enabled, the word Remote will always be displayed on the lower left
side of the display screen.