Lists available Flex-Pro pump models based on series and tube material.
Details pressure, temperature, voltage, dimensions, and motor speed capabilities.
Lists materials used for wetted and non-wetted components, pump head, and rollers.
Highlights self-priming, TFD system, SCADA inputs, and precision rollers.
Lists safety and compliance certifications like ETL, CSA, and CE directives.
Guidance on choosing a suitable location and mounting the pump securely.
Provides physical dimensions for A3 and A4 series pumps and mounting hole spacings.
Instructions and diagrams for fitting the injection/check valve and suction strainer.
Details on connecting power, including wiring compartment, cord options, and safety.
Explains terminal connections for inputs, outputs, and power with schematic diagrams.
Explains the function of each button on the Flex-Pro pump's control panel.
Describes how to navigate the pump's menu system using buttons and prompts.
Outlines the structure of the configuration menu for various settings.
Step-by-step guide to change the display language of the pump.
Instructions on selecting and viewing different units of measure for pump output.
Procedure to restore the pump's settings to their original factory configuration.
How to set a maximum motor RPM to prevent overfeeding.
Guide to calibrating the pump's maximum flow rate for accurate output.
Manually control pump speed by setting motor speed percentage.
Configure remote pump control using a 4-20 mA signal input.
Configure remote pump control using a 0-10 VDC signal input.
Configure remote pump control using a frequency (Hz) signal input.
Control pump with an incoming pulse signal for batch operations.
Set a repeating cycle for pump speed and run time.
Configure precise dispensing of a set volume at a specified pump speed.
Set Parts Per Million (PPM) dosing for fixed fluid volumes.
Configure PPM dosing based on an external flow meter's pulse output.
Configure remote start/stop functionality using dry contact closures.
Set up FVS to detect flow interruptions and trigger an alarm.
Configure TFD system sensitivity to detect chemical leaks.
Set pump operation to remote control only, local control only, or disabled.
Monitor and reset the pump tube's operational timer.
Configure configurable 4-20 mA or frequency output signals for external devices.
Assign relay outputs to pump functions like TFD, FVS, or run status.
Configure contact closure outputs for pump run/stop or general error.
Guidelines for weekly inspection of pump components for wear or chemical attack.
Instructions for cleaning pump parts during tube replacement and optional lubrication.
Explanation of how to reverse rotor rotation to extend tube life.
Step-by-step instructions for safely replacing the pump tube assembly.
Graphs showing flow rate versus motor RPM for different fluid viscosities.