5
© 2016 OJ Electronics A/S
Type FLP35-120/240GA English
Please note: Usually, the electrician who installed the thermostat
will have set the correct time and day of the week.
SETTINGS
DAY
MON
FRI
TUE
SAT
WED
SUN
THU
Readout
I want to know the amount of time (in percentage) during
which the heating was turned on within a certain period.
To do so, you must:
1 Press the OK button twice to activate the menu.
2 Press the Up or Down buttons until the Settings option flashes.
3 Press the OK button.
4 Press the Up or Down buttons until the Readout option flashes.
5 Press the Up or Down buttons to the select the period of inter-
est: 2 days, 30 days or 365 days. The percentage of time that
the heating was turned on will then be indicated in the upper
part of the display.
The Readout submenu also contains information about the
Software version and the type of control (Room, Floor, Regu-
lator or Room limit) selected for the Application.
(See Application for more information).
SETTINGS
READOUT
2 DAYS
30 DAYS
365 DAYS
SOFTWARE
APPLICATION
EXIT
Oset Temperature
I want to adjust the dierence in temperature between
the thermostat and my room thermometer.
To do so, you must:
1 Press the OK button twice to activate the menu.
2 Press the Up or Down buttons until the Settings option flashes.
3 Press the OK button.
4 Press the Up or Down buttons until the Oset Temp option
flashes.
5 Press the Up or Down buttons to set the oset temperature (in
steps of 1°).
6 Press the OK button.
7 Select Exit to exit the option.
Oset is used to compensate for any dierence between the
thermostat and a room thermometer. It is possible to adjust the
oset by up to +/- 10 °C or +/- 18 °F. Once the oset has been set
correctly, the thermostat will display the same temperature as the
thermometer.
If, for example, the thermostat shows 1° too much, the oset
should be set to 1°. The temperature will then be set 1° lower.
SETTINGS
OFFSET TEMP
Application
I want to select the type of temperature control.
To do so, you must:
1 Press the OK button twice to activate the menu.
2 Press the Up or Down buttons until the Settings option flashes.
3 Press the OK button.
4 Press the Up or Down buttons until the Application option
flashes.
5 Press the Up or Down buttons to select one of the four types
of control:
Room: The built-in room sensor is used. Only room tempera-
ture is controlled.
Floor: The floor sensor is used. Only floor temperature is
controlled. If you choose this option, you must set a maximum
and minimum temperature for the floor sensor.
Regulator: The thermostat functions as a simple regulator and
no sensors are used.
Room limit: The thermostat controls room temperature while
using the external temperature sensor as a limit sensor. If you
choose this option, you must set a maximum and minimum
temperature for the limit sensor, so that the thermostat will
switch the heating on or o if the floor temperature reaches
the maximum or minimum temperature respectively. This can,
for instance, be used to avoid excessively high temperatures
on wooden flooring (maximum limit) or excessively cold tem-
peratures on tiled/stone flooring (minimum limit).
6 Press the OK button.
7 Select Exit to exit the option.
Please note: Usually, the electrician who installed the thermostat
will have selected the correct type of temperature control for your
application.
ROOM
FLOOR
REGULATOR
ROOM LIMIT
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
Factory setting: Monday
Factory setting: 0.0 °F
Factory setting: FLOOR