5
2.0 Manufacture
2.1 The materials used to manufacture the piece parts in FloPlasts AAV’s are dened in secon 1 above and in the main
use convenonal injecon moulding techniques. The EPDM poppet seal and the ‘O’ rings used to seal the lids are pur-
chased from rubber manufacturing specialists and are assembled on the poppets and bodies respecvely.
2.2 As a part of the assessment and ongoning surveillance of product quality under FloPlast’s Kitemark accrediaon
(KM51247), BSI has:
• Agreed with FloPlast the quality control procedures and product tesng to be undertaken.
• Assessed and agreed the quality control operated over batches of incoming materials.
• Monitored the producon process and veried that it is in accoirdance with the documented process.
• Evaluated the process for manufacturing non-conformies.
• Checked that all equipment has been properly tested and calibrated.
Undertaken to carry out the above measures as a part of the surveillance process to verify that the specicaons and
quality control being operated by FloPlast are being maintained.
2.3 The management systems of FloPlast have been assessed and cered as meeng the requirements of BS EN ISO
9001: 2015 by Brish Standards Instute (Cercate KF501414).
3.0 Delivery and site handling
3.1 FloPlast AAV’s, complete with their adaptors, (where applicable), along with installaon instrucons are supplied in
cardboard boxes and polyethylene bags, to limit the risk of contaminaon or damage. All valves must be stored upright
in their boxes unl required for use.
3.2 The legend of the distributor is incorporated in to the lid of the product and is shown on the packaging. In addion,
all FloPlast valves have CE mark designaon A1 to BS EN 12380: 2002, the details of which appear on the boxes.
4.0 Design Consideraon - General
4.1 The FloPlast Air Admiance Valves when used in above-ground drainage systems designed with BS
12056-1: 2000 and BS 12056-2: 2000, the valves are sasfactory for use to:
• admit air under condions of reduced pressure in the discharge pipes and prevent water seals in traps
from being drawn or evacuated
• prevent the release of foul air from the drainage system, and
• contribute to the venlaon of the main drain to which the discharge stack incorporang the valve is
connected
4.2 The 32mm and 40mm valves are designed for connecon to waste pipes to prevent water loss from trap seals by
self and induced siphonage arising from water ow in small diameter branch discharge pipes.
4.3 The 50mm valve is for use on branch discharge pipes.
4.4 The 82mm, 100mm and 110mm valves are desigined for use on discharge stacks up to 45 metres or 10 storeys high.
4.5 The FloPlast valves are designed for use in associaon with each other or separately.
5.0 Praccability of installaon
FloPlasts AAV’s are designed to be installed by a competent general builder, or a contractor experienced in these types
of products.