EasyManua.ls Logo

FLORABEST FTS 1100 D4 - User Manual

FLORABEST FTS 1100 D4
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SUBMERSIBLE DIRTY WATER PUMP
FTS 1100 D4
IAN 291597
SCHMUTZWASSER-TAUCHPUMPE
Originalbetriebsanleitung
®
SUBMERSIBLE DIRTY WATER PUMP
Translation of the original instructions
ΒΥΘΙΖΟΜΕΝΗ ΑΝΤΛΙΑ
ΑΠΟΣΤΡΑΓΓΙΣΗΣ ΑΚΑΘΑΡΤΟΥ ΝΕΡΟΥ
Μετάφραση των αυθεντικών οδηγιών λειτουργίας
291597_flo_Schmutzwassertauchpumpe_cover_IE_NI_CY.indd 2 15.12.17 10:18

Table of Contents

Questions and Answers

  • M
    Molly DavidsonAug 4, 2025
    Why does my FLORABEST FTS 1100 D4 Water Pump switch off after a short period?
    • J
      Jaime SmithAug 4, 2025
      If your FLORABEST Water Pump switches off after a short period, it might be due to severe water pollution causing the motor contactor to disconnect the pump. To resolve this, pull out the power plug and clean both the pump and the shaft. Alternatively, the water temperature may be too high, leading the motor contactor to break. Ensure that the water temperature does not exceed 35 degrees.
  • R
    Richard JonesAug 13, 2025
    What to do if my FLORABEST Water Pump has no discharge?
    • L
      Larry JohnsonAug 13, 2025
      If your FLORABEST Water Pump has no discharge, check for a buckled pressure hose and repair any bent points. Also, there might be trapped air in the pump casing. To fix this, tip the pump underwater until the air escapes.
  • J
    Joyce BennettAug 25, 2025
    Why doesn't my FLORABEST FTS 1100 D4 Water Pump switch off?
    • H
      Heather WrightAug 25, 2025
      If the FLORABEST Water Pump does not switch off, it could be due to the float switch being unable to drop. To resolve this, ensure the pump is correctly set up on the pit base.

Summary

Special instructions for safe operating

Areas of Application

Technical Data

Performance data

Graph showing pump performance based on flow rate.

Notes on Safety

General notes on safety

Important safety guidelines for operating the equipment.

Initial Operation

Adjustment of the float switch

Operational start-up

Cleaning;Maintenance;Storage

Waste Disposal;Environmental Protection

Guarantee

Troubleshooting

Replacement parts;Accessories

FLORABEST FTS 1100 D4 Specifications

General IconGeneral
Power Consumption1100 W
Max. Delivery Height45 m
Max. Flow Rate4600 L/h
Max. Suction Height8 m
Max. Pressure4.5 bar
Cable Length1.5 m
Protection TypeIPX4
Voltage230 V
Frequency50 Hz
Hose Connection1 inch
Inlet/Outlet Diameter1 inch