40
Schmidt Armaturen
AI - FlowTop
Standard Bonnet
with V-Ring Balancing
SPM - Code : V7xx xxONx
Disassembly
Step 06
Remove plug unit (2.2, 2.3, 2.4) with balancing from
the bonnet
CAU TION !
Do not damage high quality stem surface
and plug guide !
Remove fl at gasket (1.2)
CAU TION !
Remove remains of fl at gasket (1.2)
in the bonnet and the balancing.
Do not damage sealing surface !
Reassembly
Step 06
Reassembly takes place in reverse order.
CAUTI ON !
Clean parts and check sealing surfaces
for damage
Check plug guide and packing area in the bonnet
( Damage to the packing packing area will lead to
early leaks in the packing unit )
Usenewatgasket(1.2)!
Grease balancing (2.24) lightly inside and place
on the plug up to as far as the guide band groove
Lay driving band (2.21) in place and push
balancing (2.24) "halfway"
CAUTI ON !
Lubrication as per Table 06 (Page 65)
Do not grease stem !
Lay  at gasket (1.2) in the body
- see also "Reassembly" Step 0 3
Place plug unit in the body with the balancing
Lay  at gasket (1.2) on the balancing (2.24)
Put bonnet in place

Other manuals for Flowserve FlowTop V726