7
Schmidt Armaturen
AI - FlowTop
Disassembly
Step 01
Unscrew hexagon nuts (1.4)
Reassembly
Step 01
Grease stud screws
CAUTION !
Lubrication as per Table 06 (Page 65)
Screw hexagon nuts in place (1.4) and tighten in a
diagonally opposite sequence using the torque wrench
CAUTION !
Nut tightening moment (1.4)
as per Table 01 (Page 64)
When tightening the nuts pay attention to the
alignment of the plug ( do not rub or insert the
plug in the open / closed movement )
Tighten the hexagon nuts of the gland (3.6)
using the torque wrench
CAUTION !
Tightening moment of the hexagon nuts (3.6)
as per Variant drawing (Page 61 - 63)
Three Flange Valve
SPM - Code : V7xx DxVNA