Note: Cut off power prior to discharging the water.
Self-cleaning waterway maintenance:
Self-cleaning Waterway Maintenance
When the self-cleaning waterway is blocked,
there is no water coming out during
self-cleaning process.
Current-limiting nut
Current-limiting shaft
Deodorizing Device Maintenance
Unscrew the screws, take out the deodorant box, and replace the none-photocatalyst.
→ It is recommended to replace the none-photocatalyst after 3 years of use (the specific life
span depends on the environment).
→ If you need to replace the none-photocatalyst, please purchase it in the official online store.
1. Turn off the angle valve.
2. Unplug the power plug, cut off the power.
3. Remove the seat, press current-limiting shaft in the middle with a flat-blade screwdriver, then
reinstall the seat, and open the inlet valve.
4. If there is still no water coming out after pressing current-limiting shaft, use a flat-blade screwdriver
to unscrew current-limiting nut, remove current-limiting shaft, and clean it with a toothbrush or small
brush. After cleaning, replace current -limiting nut and current-limiting shaft to the restrictor In the
device, then reinstall the seat, and open the inlet valve.
Deodorizing
cartridge
None-photocatalyst
Filter cleaning for pressure-maintaining valve
1. Close angle valve.
2. Pull out the power plug and cut off the power.
3. Disassemble the cover and unscrew the filter
connector with a screwdriver.
4. Take out the filter assembly with nipper pliers.
5. Brush the filter assembly with a toothbrush and rinse
the filter sediment with clean water.
6. After cleaning, put the filter assembly and filter connector
back to the original position and tighten it with a screwdriver.
Tips: When cleaning, do not lose or damage the sealing ring on the filter
assembly and the filter connector, otherwise it will cause water leakage.
Filter