Warning. Read before using the Meter
To avoid possible electrical shock or personal injury, follow these guidelines:
µ Use the Meter only as specified in this manual or the protection provided by the Meter might be impaired.
µ Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. If in doubt, have the
Meter serviced.
µ Always use the proper terminals, switch position, and range for measurements.
µ Verify the Meter's operation by measuring a known voltage.
µ Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and earth
ground.
µ Use caution with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. These voltages pose a shock hazard.
µ Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or
capacitance.
µ Do not use the Meter around explosive gas or vapor.
µ When using the test leads, keep your fingers behind the finger guards.
µ Remove test leads from the Meter before opening the Meter case or battery door.
Symbols
B
AC (Alternating Current)
Fuse
F
DC (Direct Current)
P
Conforms to European Union directives
F
B
DC/AC
$
Canadian Standards Association
Earth ground
Double insulated
W
Important Information; see manual
X
Hazardous Voltage
5"
Battery (Low battery when shown on
display)
!
Underwriters Laboratories, Inc.
Meter in accordance with IEC 61010-1. 54CJ
s
Inspected and licensed by TÜV
(Technischer Überwachungs Verein)
Product Services
;
N10140
Conforms to relevant Australian standards
#
VDE (Verband Deutscher Electroniker)