Configuration C
Summary: parallel charging.
Components:
1 PowerLab 6
1 power source
1 Safe Parallel Adapter for each pack (do not use standard adapters)
2 or more packs (above 9 packs in parallel, you are responsible for determining
the charge/discharge current for each pack)
Optional FUIM3 for computer support
PowerLab 6 mode (Normal or Expansion Channel): Normal.
PowerLab 6 maximum charge power: up to 500W charge to each of two packs
charged in parallel using 30VDC/1200W power source.
Constraints:
1 pack per adapter.
Check pack polarity.
Same cell count for all packs.
Use discharge leads.
(Illustration next page)