9.0 OPERATING THE APPLIANCE - CONTINUED
8
GB IE
© 2019 Focal Point Fires plc.
Setting temperature
NOTE: This setting is only applicable for the temperature in standard heating mode, not for the temperature in the timer mode. The default
set temperature is 25°C.
NOTE: The heater only starts working when the set temperature is higher than the room temperature.
Press the + or – key to set the temperature, which ranges from 15 to 30°C.
After the temperature setting has been completed, the display flashes about 5 seconds, then shows the room temperature.
Setting timer
Up to 10 different timer settings can be programmed.
Each timer setting has its day, power-on time and power-off time.
The maximum duration of each timer setting is 23 hours 50 minutes.
If the power-off time of the timer setting falls on the following day, it is unnecessary to set the day-just set the power-off time.
Press the TIMER SET key, the timer number starts blinking (01-10).
Press the + or – key to select a timer number.
Press the TIMER SET key, the cursor on the left side of the day blinks.
Press the ▲ or ▼ key to move the cursor to the corresponding day. Press the + key to add a corresponding day, or press the - key to delete a
day.
Press the TIMER SET key to set the on time. The hour digit starts blinking.
Press the + or – key to set the hour.
Press the TIMER SET key. The minute digit starts blinking.
Press the + or – key to set the minute.
Press the TIMER SET key to set the off time. The hour digit starts blinking.
Press the + or – key to set the hour.
Press the TIMER SET key. The minute digit starts blinking.
Press the + or – key to set the minute.
Press the TIMER SET key. The temperature digit starts blinking.
Press the + or – key to set the temperature.
Press the TIMER SET key to continue with the timer setting or press the OK key to confirm the setting.
Viewing the timer setting
Press the TIMER SET key.
Press the + or – key to check the power-on time of the set timers one by one.
To check the power-off time, press the ▲ key.
Press the + or – key to check the power-off time of the set timers one by one.
To delete selected setting, press the C key.
Activation timer
Press the TIMER ON/OFF key to activate the timer function.
NOTE: When the timer is active, the heating level must be manually selected. If the heater function is not selected; only the flame effect goes
on at the set power-on time.
Automatic heating mode
Press the IC key to activate automatic heating mode. The AUTO icon appears on the display.
When the automatic heating is turned on, the heater automatically changes the heating level depending on the set temperature and the ambi-
ent room temperature.
10.0 SAFETY CUT-OUT SYSTEM
This appliance has a safety cut-out system fitted which will activate if the air inlets or heater outlets are obstructed. For safety reasons the fire
WILL NOT switch on again automatically.
The following procedure must be carried out before the fire can be operated again:
1. Unplug the power supply cable at the outlet socket and place all switches to off at the appliance.
2. Leave the fire OFF for a period of not less than 15 minutes, ensuring any obstructions are removed.
3. Plug in the power supply cable at the outlet socket, and then switch on at the appliance.
If the appliance fails to operate correctly, repeat the above procedure. If an attempt to switch on is made before the safety cut-out has reset,
the heaters may cut-out for a further period of time. If the sequence has been followed correctly and the heaters still fail to function, check the
power supply cable plug is plugged in at the outlet socket. If this is not the cause, call an electrician.