EasyManuals Logo

Focus FC-7664 User Manual

Focus FC-7664
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
communication
indicator light
Address DIP
Terminal
block
A
B
Mode Selection
Up
Down
Exit
Entry
Short circuit: wireless mode
Open circuit: wired mode
Red
Blue
Grey
Black
Red
Grey
Blue
Black
B terminal block
connect with the
panel or zone
expansion board,
please refer to left
Explanatory Diag
ram.
connect to panel
connect with zone
expansion board
Terminal block
Wiring diagramWiring diagram
FC-7664
Wireless coding is compatible with all of wireless products of our company, except remote controller,
emergency button.
Note: when you set it as wireless mode, please choose short circuit of mode selection ,then enter
zone expansion board setting status
Note: when you set it as wireless mode, please choose short circuit of mode selection ,then enter
zone expansion board setting status
Wireless codingWireless coding
Note: When the communication is normal, LED 1,2 flashing .
When code the wireless device, LED 1,2,4,8,16 (BIN) is zone indicator light.
Note: When the communication is normal, LED 1,2 flashing .
When code the wireless device, LED 1,2,4,8,16 (BIN) is zone indicator light.
User manual for FC-7664 zone expansion board
It is an optional fitting of FC-7664, can expand 24 zones. It can be used as wired or wireless
extensions, can connect with 3 expansion boards when used as wired, each board has 8 zones,
distinguished by address. Can only connect with 1 expansion board when used as wireless, it
can expand 24 zones, please preset DIP switch before you power on the expansion board. At the
same time , you must make sure expansion zone is enabled in FC-7664 system menu.
FC-7664 can expand 24 zones via zone expansion board, but it is alternative from zone
expansion board and keypad zone, it detect zone expansion board in priority, when BUS detected
zone expansion board, keypad zone is ignored automatically, when didn t detect zone expansion
board in the continuous 15s, the keypad zone will be enabled automatically.
Mode Selection
B Terminal block
Note: the wire between the panel and expansion board can not be more than 1m.Note: the wire between the panel and expansion board can not be more than 1m.
Terminal
block
board 1 board 2 board 3
You can set the zone expansion board after you entering project setting. Firstly , finish DIP switch setting
for reference DIP switch as below, then connect the zone expansion board with the control panel, the
communication indicator light will flashing, you can input your password to enter setting status from FC-
7664, then 5 LED light will flashing at the same time, press Entry key last for 3s, the 5 LED light will
all off, it indicate you has entered zone expansion board setting status, after finishing setup, please press
Exit key to exit the system.