EasyManuals Logo

FOR-A FA-9500 Quick Setup Guide

FOR-A FA-9500
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
POWER switch
Pressing the "" side turns on the power.
2
LOCK button
Press and hold down to lock the front panel operation. Press and hold down
again to unlock.
3
BY-PASS
button
Bypasses input signals (video and audio). The input signals are directly
output when the BY-PASS button is pressed (lit).
4
EVENT button
Used to save and load events.
5
Status indicator
VIDEO IN
green
Input signal present
in the selected
connector
REMOTE
green
Unlit
No input signal in
the selected
connector
Unlit
AUDIO IN
green
An audio signal
present
DC
POWER
Red
Unlit
No audio signal
Unlit
GENLOCK
green
Genlock signal
present
FAN
ALARM
Red
Unlit
No genlock signal
input
Unlit
6
Menu display
Used to display menus and make operational settings
7
Controls
(F1-F4)
UNITY buttons
Used to change operational settings. Turn and select values.
The Unity buttons return the settings to the default values.
8
Arrow buttons
Single-arrow
Used to move between parameters. (lights if accessible)
Double-arrow
Used to move between menus. (lights if accessible)
9
Menu buttons
Used to select menus.
FA-9500
Quick Setup Guide
Packing list: FA-9500 (1), Quick Setup Guide (1) CD (including Operation Manuals), AC cord (1),
AC cord retaining clip (1 set), Rack mount bracket set (1 set)
Option items: FA-95RU, FA-95PS (with AC cord, AC cord retaining clip (1 set), FA-10DCCRU
(Items installed into option slot A/B) FA-95DACBL, FA-95D-D, FA-95DE-E, FA-95AIO (with
PC-3307-1 cable), FA-95ALA
Software option: FA-95CO
2. Installing the AC Cord Retaining Clip
After connecting the AC cord, secure the AC cord with the supplied ladder
strap/retaining clip assembly to prevent accidental removal from the FA-9500. Be sure
to install the AC cord retaining clip before mounting the unit into a rack.
1) Wrap the retaining clip around the AC cord. (with the anchor of the ladder strap
toward the unit.)
2) Insert the anchor into the hole next to the AC IN socket.
3) Lightly fasten the clip around the AC cord.
4) Plug in the power cord.
5) Slide the clip on the ladder strap toward the plug.
6) Fasten the clip tightly.
7) Gently pull on the AC cord to ensure it is secured.
Make sure that the LOCK button LED on the front panel is unlit before starting an
operation. If LOCK button LED is lit orange, all operations on the front panel except
the LOCK button are disabled. Press and hold the LOCK button to unlock the
operations.
5. Connecting via a WEB Browser
Open a web browser on your computer, and enter the address as
http://192.168.0.10/ (factory default setting) in the address bar.
Press the [Enter] key to connect to the FA-9500.
The login page is displayed.
Click Login.
The authentication dialog appears.
Enter your user name and password. (The default user name and
password are set at the factory.)
User name:FA-9500
Password: foranetwork
See section 9. Control via WEB Browser in the FA-9500 Operation
Manual for details on Web browser control screens.
* Complete connections before turning the power of the unit on.
2)
4)
3)
5)
6)
1. Rear Connectors
4. Connecting a Computer
3. Front Operation Panel
ANALOG COMPONENT I/O
FA-95AIO option
Analog component input/output connectoruse with the
supplied PC-3307-1 cable.)
Refer to sec. 16. FA-95AIO Option for details on connectors.
The FA-9500 network settings must be adjusted for your network after
purchase.
The FA-9500s LAN1 IP address is set to 192.168.0.10 at the factory.
Set the IPaddress and subnet mask of the computer as follows:
IP address: 192.168.0.1 to 192.168.0.254 (except 192.168.0.10)
Subnet mask: 255.255.255.0
In Windows, open the Internet Protocol (TCP/IP) Properties window.
The network settings must be made in the window. See the users
manual of your computer for details.
See section 9-8 Network Settings in the FA-9500 Operation Manual for
details on changing the FA-9500s IP address.
The FA-9500s IP address can be checked in the NETWORK INFO
menu (menu page 197). To go to the NETWORK INFO menu, press the
STATUS/OTHER button, then a single-arrow button.
*1 Refer to the Operation Manual section 12. Analog Audio Connection for details on the
Analog audio connector.
*2 Refer to the Operation Manual section 14. REMOTE for details on the Remote control
connector.
FA-95DACBL option
Digital audio output connectors
3/4 5/61/2 7/8
FAN2
3/4 7/8
FAN1
5/6
BA
COMPO SITE
1/2
LAN2
SDI
REMOTE
LAN1
COMPO SITE
OUT3OUT2IN 1
SDI
ANALOG AUDIO
LAN2
DIGITA L AUDIO IN/OUT
OUT4OUT1 IN2 OUT1 OUT2IN
A
C
100-240V 50/60H
z IN
2
DIGITA L AUDIO OUT
S
E
R
.
N
O
.
GENLOCK IN
AC100-240V 50/60Hz IN 1
Digital audio input/output connectors
(Will be input connectors when the FA-95DACBL is installed.)
Direct connection using a crossover LAN cable is also possible.
Connection using a hub
AC100 - 240V 50/60 Hz IN 1
FAN2
SER. NO.
LAN2LAN1
REMOTE
DIGITAL AU DIO IN / O UT
7 / 85 / 63 / 41 / 2
ANALOG AUDIO
GENLOCK IN
COMPOSITE
OUT2OUT1IN
B
OUT4OUT3IN2OUT2OUT1
SDI
IN1
A
FAN1
AC100 - 240V 50/60 Hz IN2
Straight-through
LAN cable
PC
LAN1
Reference signal input connector
FA-95D-D/DE-E option
OUTIN REF IN
Dolby E
Digital audio input connector
Digital audio output connector
AC Power connector 1
AC100 - 240V 50/60 Hz IN 1
FAN2
SER. NO.
LAN2LAN1
REMOTE
DIGITAL AUDIO IN / OUT
7 / 85 / 63 / 41 / 2
ANALOG AU DIO
GENLOCK IN
COMPOS ITE
OUT2OUT1IN
B
OUT4OUT3IN2OUT2OUT1
SDI
IN1
A
FAN1
AC100 - 240V 50/60 Hz IN2
HD/SD-SDI input connector 1
HD/SD-SDI output connector 1, 2
HD/SD-SDI input connector 2
HD/SD-SDI output connector 3, 4
Analog composite input connector
Analog composite output connector
Genlock input connector
Ground terminal
Ethernet port (for future use)
Ethernet port
Digital audio input/output connector
FAN1
SLOT A
SLOT B
Analog audio Input/output connector *1
Remote control connector*2
FAN2
AC Power connector 2
MASTER
CONV2
OUT SEL
MODE
VIDEO
AUDIO
ANALOG
CONV1
IN SEL
DOWNMIX
STATUS
OTHER
C C
AES AUDIO
CLIP
DELAY
AUDIO SYS
VIDEO SYS
AUDIO OP
VIDEO OP
MAPPING
A V O
PROCESS
SDI AUDIO
F4
UNITYUNITYUNITYUNITY
F3
F2
F1
F A - 9 5 0 0
DISPLAY AREA
HD / S D FR A M E S YS N C HR O N I ZE R
VIDEO IN
AUDIO IN
GENLOCK
REMOTE
FAN ALARM
DC POWER
BY-PASS
LOCK
EVENT
ON
OFF
POWER
F1
F2
F3
F4

Other manuals for FOR-A FA-9500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FOR-A FA-9500 and is the answer not in the manual?

FOR-A FA-9500 Specifications

General IconGeneral
BrandFOR-A
ModelFA-9500
CategorySignal Processors
LanguageEnglish

Related product manuals