1 POWER switch Pressing the "" side turns on the power.
2
FS1/LOCK
button
Used to select FS1. Press and hold down to lock the front panel operation.
Press and hold down again to unlock. In the FA-9520 mode, locks only the
operation for FS1.
3
FS2/LOCK
button
Used to select FS2. In the FA-9520 mode, locks the front panel operation for
FS2 when pressed and held down. Press and hold this button down again to
unlock.
4 EVENT button Used to save and load events.
5
Status indicator
VIDEO IN
green
Input signal
present in
FS1/FS2
REMOTE
green
CONTROL SETTING
is set to REMOTE
Unlit
No input signal
in FS1/FS2
Unlit
CONTROL SETTING
is set to LOCAL
AUDIO IN
green
Assigned audio
signal present
DC
POWER
Red Power failure
Unlit
No assigned
audio signal
Unlit Normal power supply
GENLOCK
green
Genlock signal
present
FAN
ALARM
Red Fan failure
Unlit
No genlock
signal input
Unlit All fans normal
6 Menu display Used to display menus and make operational settings
7 Controls
(F1-F4)
UNITY buttons
Used to change operational settings. Turn and select values.
The Unity buttons return the settings to the default values.
8 Arrow buttons
Single-arrow Used to move between parameters. (lights if accessible)
Double-arrow Used to move between menus. (lights if accessible)
9
Menu buttons
Used to select menus.
FA-9520
Quick Setu
p
Guide 3rd Edition
The F
A
-9520 has 2 operational modes; F
A
-9500 mode, in which
the unit operates/functions almost the same as the former
FA-9500, and FA-9520 mode with 2 independently operational
frame synchronizers. This quick setup guide mainly describes
operation in FA-9520 mode. To change the mode, see
Operation Manual section 7-2. “MU OPERATION”.
Packing list: FA-9520 (1), Quick Setup Guide (1) CD (including
Operation Manuals), AC cord (1), AC cord retaining clip (1 set),
Rack mount bracket set (1 set)
Option items: FA-95RU, FA-95PS (with AC cord, AC cord retaining
clip (1 set), FA-95DACBL (installed before shipment), FA-95D-D,
FA-95DE-E, FA-95AIO (with PC-3307-1 cable), FA-95ALA
Software option: FA-95CO
POWER
ON
OFF
PS1/LOCK
PS2/LOCK
EVENT
VIDE O IN
GEN LOCL
REM OTE
AUDIO IN
FAN ALARM
DC P OWER
F 1
F 2
F 3
F 4
F A - 9 5 2 0HD / SD FRAME SYNCHRONIZER
DISPLAY
F 1
UN ITY
F 2
UN ITY UN ITY
F 3
F 4
UN ITY
PROCESS
SDI AUDIO
MA PP I NG
VI DEO OP
AU DIO OP
C C
A V O CLIP
DELAY
VID EO S YS
AUDI O S YS
AES AU DIO
CONV1
ANALOG
IN SEL
DOWNMIX
STATUS
OT HER
CONV2
MA ST E R
OUT SE L
MODE
VIDEO
AUDIO
2. Installing the AC Cord Retaining Clip
After connecting the AC cord, secure the AC cord with the supplied ladder
strap/retaining clip assembly to prevent accidental removal from the FA-9520. Be sure
to install the AC cord retaining clip before mounting the unit into a rack.
1) Wrap the retaining clip around the AC cord. (with the anchor of the ladder strap
toward the unit.)
2) Insert the anchor into the hole next to the AC IN socket.
3) Lightly fasten the clip around the AC cord.
4) Plug in the power cord.
5) Slide the clip on the ladder strap toward the plug.
6) Fasten the clip tightly.
7) Gently pull on the AC cord to ensure it is secured.
Make sure that the FS1/LOCK and FS2/LOCK button LEDs are lit green or unlit
before starting an operation. If FS1/LOCK and/or FS2/LOCK button LED(s) are lit
orange, all operations on the front panel for FS1 and/or FS2 except the LOCK
button(s) are disabled. Press and hold the FS1/LOCK and/or FS2/LOCK button(s)
that are lit orange to unlock the operations.
5. Connecting via a WEB Browse
r
Open a web browser on your computer, and enter the address as
http://192.168.0.10/ (factory default setting) in the address bar.
Press the [Enter] key to connect to the FA-9520.
The login page is displayed.
Click Login.
The authentication dialog appears.
Enter your user name and password. (The default user name and
password are set at the factory.)
User name: fa9520
Password: foranetwork
See section 9. “Control via WEB Browser” for details on Web browser
control screens.
* Complete connections before turning the power of the unit on.
2)
4)
3)
5)
6)
1. Rear Connectors
4. Connecting a Compute
r
3. Front Operation Panel
ANALOG COMPONENT I/O
FA-95AIO option
A
nalog component input/output connecto
r
use with the
supplied PC-3307-1 cable.)
Refer to sec. 16. FA-95AIO Option for details on connectors.
The F
A
-9520 network settings must be adjusted for your network after
purchase.
The FA-9520’s LAN1 IP address is set to 192.168.0.10 at the factory.
Set the IPaddress and subnet mask of the computer as follows:
IP address: 192.168.0.1 to 192.168.0.254 (except 192.168.0.10)
Subnet mask: 255.255.255.0
In Windows, open the Local Area Connection Properties dialog box,
and open the Internet Protocol (TCP/IP) Properties window. The
network settings must be made in the window. See the user’s manual of
your computer for details.
See section 9-8 “Network Settings” for details on changing the
FA-9520’s IP address.
The FA-9520’s IP address can be checked in the NETWORK INFO
menu (menu page 197). To go to the NETWORK INFO menu, press the
STATUS/OTHER button, then a single-arrow button.
*1 Refer to the Operation Manual section 12. “Analog Audio Connection” for details on the
Analog audio connector.
*2 Refer to the Operation Manual section 14. “REMOTE” for details on the Remote control
connector.
FA-95DACBL option
Digital audio output connectors
3/4 5/61/2 7/8
FAN2
3/4 7/8
FAN1
5/6
BA
COMPOSITE
1/2
LAN2
SDI
REMOTE
LAN1
COMPOSITE
OUT3OUT2IN1
SDI
ANALOG AUDIO
LAN2
DIGITAL AUDIO IN/OUT
OUT4OUT1 IN2 OUT1 OUT2IN
AC100-240V 50/60Hz IN 2
DIGITAL AUDIO OUT
S
E
R
.
N
O
.
GENLOCK IN
AC100-240V 50/60Hz IN 1
Digital audio input/output connectors
(Will be input connectors when the FA-95DACBL is installed.)
Direct connection using a crossover LAN cable is also possible.
Connection using a hub
AC100 - 240V 50/60 Hz IN 1
FAN2
SER. NO.
LAN2LAN1
REMOTE
DIGITAL AUDIO IN / OUT
7 / 85 / 63 / 41 / 2
ANALOG AUDIO
GENLOCK IN
COMPO SITE
OUT2OUT1IN
B
OUT4OUT3IN2OUT2OUT1
SDI
IN1
A
FAN1
AC100 - 240V 50/60 Hz IN2
Straight-through
LAN cable
PC
LAN1
Reference signal input connector
FA-95D-D/DE-E option
OUTIN REF IN
Dolby E
Digital audio input connector
Digital audio output connector
AC Power connector 1
AC100 - 24 0V 50/60 Hz IN 1
FAN2
SER. NO.
LAN2LAN1
REMOTE
DIGITAL AUDIO IN / OUT
7 / 85 / 63 / 41 / 2
ANALOG AUDIO
GENLOCK IN
COMPOSITE
OUT2OUT1IN
B
OUT4OUT3IN2OUT2OUT1
SDI
IN1
A
FAN1
AC100 - 240V 50/60 Hz IN2
HD/SD-SDI input connector 1
HD/SD-SDI output connector 1, 2
HD/SD-SDI input connector 2
HD/SD-SDI output connector 3, 4
A
nalog composite input connecto
r
A
nalog composite output connecto
r
Genlock input connector
Ground terminal
Ethernet port (for future use)
Ethernet port
Digital audio input/output connector
FAN1
SLOT A
SLOT B
Analog audio Input/output connector *1
Remote control connector*2
FAN2
AC Power connector 2

Other manuals for FOR-A FA-9520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FOR-A FA-9520 and is the answer not in the manual?

FOR-A FA-9520 Specifications

General IconGeneral
BrandFOR-A
ModelFA-9520
CategorySignal Processors
LanguageEnglish

Related product manuals