The FCC has provided guidelines for Maximum Permissible Exposure limits to RF signals (See
Table Below). The Fortem TrueView Radar operates between 15-16 Ghz (15000 Mhz).
For General Population/Uncontrolled Exposure, The FCC recommends not exceed a power
density of 1.0 mW/cm
2
for up to 30 minutes. In order to ensure you are not exceeding this
power density, please ensure the radar is not transmitting within 0.7 Meters of a person.
For Occupational/Controlled Exposure, The FCC recommends not exceed a power density of 5.0
mW/cm
2
for up to 6 minutes. In order to ensure you are not exceeding this power density,
please ensure the radar is not transmitting within 0.32 Meters of a person.