4. Line up the rack-mount bracket holes to the holes on the rack and ensure that the
FortiRPS unit is level.
5. Finger tighten four rack-mount screws to attach the unit to the rack.
6. Verify that the spacing around the FortiRPS unit conforms to requirements and that
the unit is level, then tighten the rack-mount screws with an appropriate screwdriver.
7. Plug the provided power cables into the rear of the unit, and then into grounded
electrical outlets or separate power sources, such as uninterruptible power supplies
(UPS) or power distribution units (PDU).
To install the unit on a at surface
1. Ensure that the surface onto which the FortiRPS unit to be installed is clean, level,
and stable and that there is at least 1.5in (3.8cm) of clearance on all sides to allow
for adequate airflow.
2. Attach the provided rubber feet to the bottom of the FortiRPS unit.
3. Place the unit in the designated location.
4. Verify that the spacing around the FortiRPS unit conforms to requirements and that
the unit is level.
5. Plug the provided power cables into the rear of the unit, and then into grounded
electrical outlets or separate power sources, such as uninterruptible power supplies
(UPS) or power distribution units (PDU).
To install the FortiRPS unit into a rack
1. Ensure that the FortiRPS unit is placed on a stable
surface prior to rack-mount installation.
2. Attach the provided rack-mount brackets to the sides of
the unit using the provided bracket screws.
a. If you are installing the unit into a four-post rack,
attach the rack-mount brackets with the handles
aligned with the front of the FortiRPS unit.
b. If you are installing the unit into a two-post rack,
attach the rack-mount brackets with the handles
aligned with the middle of the FortiRPS unit.
3. Position the FortiRPS unit in the rack. Ensure there is
enough room around the unit to allow for sufficient air
flow.
1.5in
1.5in
Installation
3
Caution:
Electrostatic
discharge (ESD)
can damage
your Fortinet
equipment.
Do not place
heavy objects on
the unit.
To avoid personal
injury or damage
to the unit, it is
recommended
that two or more
people install the
unit into the rack.
Note: Each power
cable should be
connected to a
different power
source. In this
way, if one power
source fails, the
other may still be
operational.
The FortiRPS unit can be placed on any flat surface, or mounted in any standard 19 inch
rack unit with the provided rack-mount brackets and screws.
Please read “Cautions and Warnings” prior to installing your device.