English
Turn the machine o.
Remove all ice from the container
Prepare the soluon by dissolving the citric acid in warm water (max 40°C), according to the quanies
shown on the Previous table.
Posion the internal switch in the cleaning posion (g 7).
Pour the cleaning product into the evaporator tray (g 8)
Turn the power to the machine on and wait for at least 2 hours.
Aer two hours, switch the machine o and drain the soluon in the evaporator tray into the cabinet
(Fig 9)
Replace the cap and pour clean water into the tray to ll it to capacity, and start the machine again.
Repeat the operaon at least 5 mes to eliminate the presence of citric acid and saniser.
Aer this me has elapsed, switch the machine o and remove the cap to discharge the water in the
evaporator tray, then replace cap.
Finally, return the switch to ice mode.
Aer the cleaning funcon, rinse the cabinet well.
If the machine remains unused for long periods: Switch the machine o;
Remove all ice from the container;
Discharge all water;
Clean carefully;
Leave the container door ajar.