EnglishEnglish
Defrost
LR150 & LR410 models have stac freezer shelves and require manual defrosts. The enre stored product
should be removed and placed in a separate freezer. Switch o the mains electrical supply and leave the cabinet
door open while placing a bowl inside to catch the water as it defrosts. Once fully defrosted dry the interior of
the cabinet and switch on the mains supply.
Do not replace frozen food into the cabinet unl it reaches its normal operang temperature.
All other models are ed with a fully automac defrost system to ensure that the evaporator coil or cooling
plate remains free from ice in normal use. ‘Melt water’ is automacally evaporated using the heat from the
refrigeraon system.
Cleaning and Maintenance
Important: Before cleaning, the unit should be put into standby and then the power supply should be turned
o at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has been completed
and the unit is dry should the cabinet be turned back on at the mains.
Suitable P.P.E (Personnel Protecve Equipment) should be worn at all mes.
Regular Maintenance:
> As and when required remove all product and shelving (beware of cold and or sharp components) from
the unit. Clean exterior and interior surfaces with mild liquid detergent, following the direcons on the
pack at all mes. Rinse surfaces with a damp cloth containing clean water. Never use wire wool, scouring
pads/powders or high alkaline cleaning agents i.e bleaches, acids and chlorines as these may cause
damage.
> Condenser Cleaning:
This should take place on a regular basis or as and when required (4 to 6 weeks) by a competent/trained
personnel.
Use a so brush or vacuum cleaner to remove dirt/dust. If there are any stubborn grease deposits le
on or through the condenser call your supplier to carry out a full service (this is normally chargeable).
Failure to maintain the condenser may invalidate the warranty of the condensing unit and cause
premature failure of the motor/compressor. Do not use a wire brush to clean the condenser. Hoover or
brush the air lter (where ed).
> All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a warm
damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry.
> Removable shelves and their supports can be removed for cleaning. The shelves are dishwasher safe;
however the vercal supports should be cleaned with warm soapy water then rinsed and dried.