Tangency
adjusting
screw
Azimuth
and
phase
adjusting
screw
Height
and
Tilt
adjusting
screw
Fig.
4.13
Adjust
the
Azimuth
and
Phase
Adjusting
Screw
for
maximum
reading
on
all
sixteen
LED
bargraph
meters
of
the
recorder.
Then,
set
the
oscilloscope
to
XY
mode
to
obtain
a
lissajous
waveform
to
check
the
phase.
Trace
for
vertical
input
alone
Trace
for
horizontal
input
alone
Fig.
4.14
Unequal
levels
If
the
trace
length
between
(X)
and
(Y)
are
not
the
same,
it
means
that
the
two
inputs
to
the
oscilloscope
are
not
of
the
same
level.
Correct
for
equal
lengths
by
the
oscilloscope
controls.
If
the
playback
head
azimuth
is
out
of
alignment,
the
following
patterns
will
result:
(A
small
misalignment
30°
out
of
phase)
outof
phase)
(A
big
one,
18
out
of
phase)
(Perfect
azimuth
0°,
in
phase)
Fig.
4.15
41