04385 Page 5 02/09/2016
REV E
4. INGESTION (Swallowing): (Uncontaminated cleaning solution) Drink 4 to 8 ounces of water
and seek medical attention. DO NOT induce vomiting.
E. Environmental
1. Avoid spilling solution. Spilled solution can create slippery conditions, clean it up immediately.
Close off area to traffic. Wear appropriate personal protective equipment to prevent eye and skin
contact. Consult the Material Safety Data Sheet for instructions on clean up and disposal.
2. Contain leaks promptly. Notify local environmental authorities if necessary.
3. Aqueous solutions, when used to clean grease and oil, must be disposed of properly.
Consult your local environmental management agency for additional guidance and other
potentially hazardous materials compliance requirements.
4. For further information consult the Material Safety Data Sheet provided by the solution
supplier.
III. Installation
1. Position reservoir on a hard, level surface in a well-ventilated area.
2. Remove the carton and open the tank cover. Remove the small parts bag from inside the tank.
Inspect for damage.
3. Mount the upper tank onto the reservoir. Secure with the
thumb screw provided.
4. Mount the switch box onto the side of the upper tank.
Secure with the thumb screws provided.
5. Connect the cam couplers on the back of the tank
between the filter assembly and the pump.
8. Fill solution reservoir to the correct level. This equipment is
designed for use only with Aqueous Based Solutions. Do
NOT add any other chemicals to the cleaning agent
including, but not limited to, kerosene, fuel oil, gasoline, or
chlorinated solutions. The use of any other solutions could
potentially cause a hazardous condition.
Capacity Model KT5000 = 30-35 gal. (113.6-132.5 L.)
Low Level = 27 gal. (102.2 L.)
9. Plug the power cord into a properly grounded power source. Check serial plate for power
requirements.
Power Requirements = 15 amp, 115 volt, 60 Hz