Installation Guide
FS-STAT-32AC
Wireless Communicating Thermostat
Caution
Failure to follow these instructions can damage the product or cause
a hazardous condition. Disconnect power during the installation of
this product. All wiring must conform to local codes and ordinances.
This thermostat is designed for use with 24 VAC systems.
For additional assistance visit www.Founten.com to request support.
Before Removing Old Thermostat
Note the colors and letter designations of the terminal connections on
the existing thermostat to assist in identifying the correct wiring
connections.
Wall Mounting
The rear cover of the thermostat is mounted to the wall. To separate
the front cover from the rear cover, simply grasp the front and back of
the thermostat firmly and pull apart.
Attach the rear of the thermostat to the wall using the included Plastic
Anchors. Position the rear cover so that the wires can be fed through
the rectangular opening in the back of the thermostat. Then mark the
locations of the mounting points on the wall. Drill a 3/16” hole for
each anchor. Insert the anchors into the wall and attach the rear
cover using the included screws. The thermostat can also be
mounted to an electrical box using the included machine screws.
1
Question and Answer IconNeed help?

Do you have a question about the Founten FS-STAT-32AC and is the answer not in the manual?

Founten FS-STAT-32AC Specifications

General IconGeneral
BrandFounten
ModelFS-STAT-32AC
CategoryThermostat
LanguageEnglish

Summary

Safety and Installation Warnings

Wall Mounting Instructions

Separating Thermostat Covers

Instructions on how to detach the front cover from the rear cover of the thermostat for wall mounting.

Attaching Rear Cover to Wall

Steps for mounting the thermostat's rear cover using anchors and screws or machine screws.

Terminal Designations Overview

Conventional System Terminals

Lists terminal designations for conventional HVAC systems, including R, Rc, C, Y, W, G, W2, Y2, and D.

Heat Pump System Terminals

Lists terminal designations for heat pump systems, including R, Rc, C, Y, O/B, G, Aux, and Y2.

Standard Wire Color Designations

Wiring Configuration Guide

Conventional System Wiring

Illustrates wiring connections for conventional systems with single or two transformers and various stages.

Heat Pump System Wiring

Illustrates wiring connections for heat pump systems with one or two stages, including auxiliary heat.

Thermostat Configuration Settings

Setting System Type via Keypad

Alternate Limited Wiring Installation