63
ENGLISH
SCHEDULED MAINTENANCE FOR THE ATS
SYSTEM - HOW TO PROCEED
Change Supply Module main-filter
To prevent damage to the pump and dosing module, the supply
module contains a filter which removes any impurities from the
AdBlue.
Please refer to the following procedure for replacement of the filter.
1. Coolant connector - 2. AdBlue inlet from tank - 3. AdBlue back-flow
to tank - 4. AdBlue outlet to Dosing Module - 5. Pressure sensor -
6. Supply Module main-filter - 7. Membrane pump - 8. 4/2 Way valve.
Filter disassembly
Unscrew and remove the filter cover (1).
Remove the equalizing element (2).
During installation of the supply module on the
equipment, take into account the minimum aperture
for filter replacement.
The minimum value is approx. 155 mm.