25
ENGLISH
Electrolyte level in batteries check
Place the batteries on a level surface, then proceed as follows.
Visually check that the fluid level is between the “Min” and “Max”
limits; in the absence of references, check that the fluid covers the
Lead plates inside the elements.
Top up with distilled water only those elements in which the level
is below the minimum.
Contact specialised technical staff if the battery needs recharging.
Have the efficiency of the battery recharging system tested if a
voltage of less than 22 V is detected with the engine running.
On this occasion, make sure that the terminals and clamps are
clean, properly locked and protected by vaseline.
Some types of battery have a single cover for all the inspection plugs.
To access the elements, use a lever as shown in the figure.
ATTENTION!
If all the elements of the battery need refilling with a
considerable quantity of distilled water, contact
specialised technical personnel in order to perform a
diagnostic check on the efficiency state of the recharge
system and battery.
ATTENTION!
The batteries contain sulphuric acid which is highly
caustic and corrosive; always wear protective gloves
and goggles when topping them up. Whenever
possible it is recommended that this control be carried
out by specialised personnel.
Do not smoke or use live flames near the batteries
during the control, and make sure that the room you
are working in is adequately ventilated.