19
4. INSTALLATION
4.1. Choice of position
easyWallbox is designed for indoor and outdoor use, only for xed wall
mounting, and therefore cannot be used in dierent spaces where its continual
movement is required.
Before installing the device, check the feasibility. In detail, the position chosen
for the installation of easyWallbox must:
be on a vertical and at surface, as shown in 4.5; weak surfaces that do not
ensure robust resistance must be avoided
allow easy connection to the power supply and the electric vehicle to charge
not be an obstacle to the movement of the electric vehicles to charge
not have material or equipment on the whole of the surface required for
the installation
respect local legislation on electrical installations, re prevention measures
and emergency exits in the installation site.
easyWallbox should not be installed on a pole/column or
pre-existing piping.
easyWallbox must not be installed in places:
at risk of explosion (EX environment)
used for escape routes
where articles may fall on it (e.g. suspended ladders or car tyres) or where
it is likely to be hit and damaged (e.g. close to a door or in vehicle operating
spaces)
where there is a risk of pressurised jets of water (e.g. because of washing
systems, power washers or garden hoses)
it cannot be installed on non-permanent walls
it cannot be installed on walls in inammable material or covered with
inammable material (e.g. wood, carpet, etc.).
In Italy, easyWallbox must not be installed in public areas,
as in IEC 61851-1.