4.2. Acceptable environmental conditions
In detail, the conditions of the room where easyWallbox is sited must be as
follows:
room temperature between -25°C and +50°C
average temperature over 24 hrs less than 35°C
maximum altitude above sea level: 2,000 metres
relative air humidity not higher than 95%.
Damage to easyWallbox caused by unsuitable environmental
conditions.
Inappropriate positioning of easyWallbox may cause damage
to the device.
Take the following into consideration when choosing the position for the
installation of easyWallbox:
avoid exposure to direct sunlight, if necessary, by installing a canopy
avoid direct exposure to the rain so that deterioration due to bad weather
does not occur
ensure sucient ventilation for the device – do not mount it inside a niche
or a closet
avoid an accumulation of heat - keep the device away from heat sources
avoid exposure to water inltration
avoid excessive leaps in temperature.
Danger of re and explosion
easyWallbox must be installed in areas where there are no
incendiary or explosive substances, such as close to petrol stations,
because any sparks triggered by its components could cause res or
explosions.