EasyManua.ls Logo

FreegoEV DK200 - Page 7

FreegoEV DK200
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-6-
P01 Panel Brightness: 1 as darkest, 2 as medium, 3 as brightest
P02 KM or Mile: 0 as KM, 1 as Mile
P03 Voltage: 24V, 36V, 48V
P04 Sleeping Mode: 0-60
0 never sleep, other numbers stand for the sleep time (1-60 min)
P05 Pedal Assist System (PAS):
the smaller the number is, the less assistance.
0, 3 Grades Mode: 1 Grade 2V, 2 Grade 3V, 3 Grade 4V
1, 5 Grades Mode: 1 Grade 2V, 2 Grade 2.5V, 3 Grade 3V, 4 Grade 3.5V, 5 Grade 4V
P06 Wheel Diameter: Unit/inch, Precision/0.1
P07 Speed Measuring Magnet: 1-100
P08 Speed Limit: 0-50 or 0-100 (Di󽗿erent Batches may di󽗿er )
Notes: if yours ranges 0-50, please set 49 at most, indicating speed limit is 49km/h.
These data are based on KM. When changing KM to Mile, the speed value on the screen
would convert to correct Miles automatically, but if you do not change the setting of
speed limit from KM to Mile.
Warning: 50/100 means no speed limit, if you set the speed limit to 50/100, please be
careful when riding.
P10 Drive Method:
0: driven by PAS. Throttle is useless at this time.
1: driven by Throttle. PAS is useless at this time.
2: driven by PAS & Throttle. Throttle is useless at Zero Start status.
P11 PAS Sensitivity: 1-24
P12 PAS Start Power: 0-5
P13 PAS magnet type: 5, 8, and 12.
P14 Controller Amp: 12A as default. 1-20A.
P15 Not in Use
P16 ODOmeter Reset: press and hold "+" for 5 seconds to reset 0 of the meter.