Packing
Safety
MPC
Genesis - Vintage
Specificaons
MPC 30 MPC 48
Cooling capacity 780 W** 1100 W**
Heang capacity 800 W 800 W
Voltage
230 V - 50Hz 230 V - 50 Hz
Current heang mode 4.4 A
Power consumpon 365 W / 2,3 A 508 W / 3,2 A
Airflow cellar side
2m 2m
Refrigerant
R134A R134A
nominal outside temperature
32°C 32°C
8 - 18 °C 8 - 18 °C
Weight 45 kg 49 kg
4.4 A
Current cooling mode 4 A
5 A
365 m3/h
310 m3/h
Temperature seng range
Airflow outside
510 m3/h
405 m3/h
Maximum volume of the cellar 30m3* 48m3*
* in a perfectly insulated room (PU 60mm on all sides).
** on the following condions: 12 ° C in the cellar / 32 ° C outside.
Power cable lenght