e180
FRIDEN
CALCULATING
MACHINE
CO..
INC.
Page
1
COUNTER
ADJUSTMENTS
93,
COUNTER
FINGER
ALIGNMENT:
Primary
Fingers
A
and
Secondary
Fingers
B
should
be
in
line
and
parallel
to
Side
Frames.
The
spacing
of
the
Fingers
is
5/8"°
between
centers.
Adjust
pyforming.
A
suitable
gauge
may
be
made
from
an
Accumulator
Zero
Stop
Slide
#90050.
MODEL
STW
SECONDARY
FINGER
G@)
PRIMARY
FINGER
B
os
8
&
———
==
tr
raid
oes
SECONDARY
FINGERS
94.
COUNTER
SPIRAL:
No
more
than
ane
sec-
ondary
Finger
skould
touch
the
Secondary
Cam
on
the
Counter
Dials
at
any
time.
Otherwise,
there
is
a
possibility
of
an
error
due
to
a
false
transfer
or
‘Secondary
Pick-up."'
This
Spiral
is
the
amount
each
Secondary
Toothis
behind
the
Tooth
to
the
right,
and
is
very
small
~
only
ap-
proximately
.004
for
each
Counter
Taoth
As-
sembly.
The
above
illustration
is
slightly
exag-
gerated
to
show
whatis
meant
by
Spiral
inthe
Counter..
When
a
Pick-up
or
Flicker
is
noted
in
Counter
Dial
to
the
Jeft
of
the
Transfer
Point,
correct
by
peening
the
Lug
on
the
Secondary
at
A
and
inthe
position
where
the
error
occurs,
PEEN
VERY
LIGHTLY.
FRIDEN
SERVICE
doesx’t
COST
the
customer
anything
compored
ta
the
DIVIDENDS
it
PAYS