PAN FULL HUMIDISTAT
0
I
PAN FULL
HUMIDISTAT
0
OFF
DRYEST
Unit operetion
1. Turn Humidistat to OFF. Plug power supply
cord into electrical outlet. Be sure to use the
correct grounding technique. (See page 4.)
2 Turn Humidistat left toward DRYEST for
normal operation. Set at 5 or 6 to start. Adjust
later, if necessary.
lt you need more dehumidification, turn
Humidistat left to a higher number. If you need
less, turn Humidistat right to a lower number.
3. Stop the unit manually by turning Humidistat
right to OFF.
De-icer control
Do not operate dehumidifier at tempem-
tures below 18.3% (65°F). The coils msy
become iced over and unit will not operate
pwerly.
Your dehumidifier is equipped with a feature to
help you get the most comfort from your new
appliance by permitting it to operate down to
18.3% (65’F). lf your dehumidifier runs when
room temperature and humidii conditions are
tow, frost can form on its evaporator coil. This
interferes with proper operation.
The De-icer Control senses frost build-up on
the evaporator coil and automatically shuts off
the compressor. The fan continues to run,
drawing air across the coil and melting the frost.
When the coil is defrosted, the compressor is
automatically restarted, and dehumidifying is
resumed.