Installation Instructions
For Hea ry Duty (FAS Models) and
Median (FAM Models) Air Conditioners
Please read ALL instructions before installing. Two people are
recommended to install this product. If a new electrical outlet
is required, have the outlet installed by a qualified electrician
before installing unit. See#5 in Preliminary Instructions
following.
Preliminary Instructions
Do the following before starting to install unit. See illustrations
below.
Check dimensions of your unit to determine model type:
Hea D" duty (FAS) Median (FAJVI)
Unit Height: 18 5/8" 17 5/8"
Unit Width: 26 1/2,, 23 V£'
Min. Window Opening: 19" 18 V2"
Min. Window Width: 31" 26 V2"
Max. Window Width: 43" 40 V£'
I. Check window opening size - the mountingparts furnished
with this air conditioner are made to install in a wooden
sill double-hung window. The standard parts are for
window dimensions listed above. Open sash to a minimum
of !9"(483mm). (FIG. 1)
2. Check condition of window - all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
FIG. 1
q 9" M_N.
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
_LI _LL ANGLE
3. Checkyour storm windows -if your stotlnwindc_w
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG. 2, or by removing
stom_window while room air conditioner is being installed.
(continued)
19" MtN_
!_" MIN 11 1/2" MIN,
.................?
] _-n-- [ BOARD THICKNESS AS
I L../-/--/< REQUIRED,ALONG
] - -v" " ENTIRE STOOL. FASTEN
STORM WINDOVV FRAME OR WITH TWO NAILS OR
OTHER OBSTRUCTION SCREWS.
P/N 220218A008