INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
40 1/8" Min.
101.9 crn Min.
13" Min.
(45.7 crn Min.) (33 crn Min.)
\\
Grounded 24" Min.
Wall Outlet (61 cm Min.)
47 _A" Max.
(120 crn)
43 ;A"
(111.1 cm)
with larger\
door open __ _
27 3A
feet extended
(91.4 cm)
Do not pinch the power supply cord between the range
and the wall.
Do not seal the range to the side cabinets.
**NOTE: 24" (61 cm) minimum clearance between the
cooktop and the bottom of the cabinet when the bottom
of wood or metal cabinet isprotected by not lessthan
1/4" (0.64 cm) flame retardant millboard covered with not
less than No. 28 MSG sheet metal, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5
mm) copper.
30" (76.2 cm) minimum clearance when the cabinet is
unprotected.
36" (91.4cm) 401/8"(101.9cm) 251/2"(64.8cm) 433/4"(111.1cm) 401/4"(102.2cm) 36" (91.4cm)standard
35%" (90cm) rain.
P/N 318200870 (0201 ) Rev. E